Theranostics 2026; 16(15):8580-8610. doi:10.7150/thno.134985 This issue Cite
Review
1. Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611, USA.
2. Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL 60208, USA.
3. Robert H. Lurie Comprehensive Cancer Center, Chicago, IL 60611, USA.
4. Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.
#Current address: Department of Radiology, University of Michigan Medical School, Ann Arbor, MI 48109, USA.
Received 2026-3-24; Accepted 2026-6-17; Published 2026-8-12
Surrogate materials enable pre-treatment prediction of intra-hepatic distribution of therapeutic radioactive microsphere, facilitating patient-specific dosimetry for transarterial radioembolization (TARE). Technetium-99m macroaggregated albumin (⁹⁹ᵐTc-MAA) has long constituted the clinical standard for SPECT-based surrogates, however, its fundamental physicochemical difference from therapeutic microspheres limits the reliability of MAA-based dosimetry and prediction for personalized treatment planning. Next-generation surrogate technology includes biodegradable polymeric microspheres engineered to closely replicate the therapeutic microsphere while affording post-procedural arterial recanalization through controlled biodegradation. Theranostic microspheres incorporating diverse radionuclides, positron-emitting PET compatible surrogates, and multimodal CT and MRI-visible surrogates have collectively expanded same-particle pre-treatment dosimetry capabilities. These material-level advances are synergistically coupled with computational dosimetry tools including artificial intelligence/deep learning algorithms for automated segmentation/dose-prediction, and Monte Carlo simulations that enhance voxel-based dosimetry precision. This review examines recent advances in surrogate materials design and integrated imaging/dosimetry methodologies that enhance TARE efficacy, safety, and personalized treatment outcomes.
Keywords: transarterial radioembolization, surrogate, microspheres, hepatocellular carcinoma, radionuclides, Yttrium-90
Hepatocellular carcinoma (HCC), the most common primary liver cancer, is the third leading cause of cancer-related mortality worldwide [1]. The majority of HCC cases about 70% are diagnosed at intermediate-to--advanced stages (BCLC stage B-D). Surgical resection and liver transplantation have been only curative interventions. However, eligibility is restricted to a minority of patients. Systemic tyrosine kinase inhibitors chemotherapy, immune checkpoint inhibitors immunotherapies, combinational chemo-immunotherapy regimes are also the therapeutic options but offer modest survival benefit. Consequently, local interventional therapies have been a primary disease management strategy across intermediate and advanced stages of HCC [2]. Among local interventional therapies, transarterial radioembolization (TARE) has been proposed as a promising treatment modality for HCC treatment [3]. The procedure involves hepatic intra-arterial infusion of radioactive microspheres, which exploit the selective tumor irradiation while minimizing damage to surrounding healthy tissues. The historical development of TARE spans more than seven decades. The earliest clinical applications employed radioactive gold in 1951, followed by the use of phosphorus-32 (32P) through the 1960s [4, 5]. Yttrium-90 (90Y) subsequently emerged as the preferred and standard radionuclide for clinical TARE. As a pure beta emitter with a physical half-life of 64.1 hours and a mean soft-tissue penetration of approximately 2.5 mm (maximum ~11 mm), 90Y delivers effective locoregional tumor irradiation within a clinically manageable timeframe while limiting off-target dose deposition [6, 7]. Although pure beta emitters like 90Y can be imaged using bremsstrahlung SPECT, the spatial resolution and quantification are limited due to its continuous energy spectrum. To address these imaging constraints, alternative radionuclides emitting both therapeutic beta and imageable gamma photons have been developed and investigated for TARE. Those radionuclides that have been investigated are summarized in Table 1.
Radionuclides for TARE
| Radionuclides | Half-life | Emission Type | β⁻ Energy (MeV) Max. (Mean) | γ Energy (KeV) | β⁻ Range in Tissue (mm) Max. (Mean) | Imaging Modalities | Application |
|---|---|---|---|---|---|---|---|
| Phosphorus-32 (32P) | 14.29 d | β⁻ (100%) | 1.71 (0.695) | No γ emission | 7.9 (3) | Bremsstrahlung SPECT | Therapy only |
| Yttrium-90 (90Y) | 64.1 h | β⁻ (100%) | 2.28 (0.933) | No γ emission | 11 (2.5) | Bremsstrahlung SPECT/90Y PET | Therapy only |
| Iodine131 (131I) | 8.04 | β⁻ (86%), γ (81%) | 0.606 (0.192) | 364 | 2.5 (0.8) | SPECT | Theranostics |
| Praseodymium-142 (142Pr) | 19.12 h | β⁻ (86%), γ (3.7%) | 2.16 (0.809) | 1.57 | 8.8 (3) | SPECT | Theranostics |
| Samarium-153 (153Sm) | 46.3 h | β⁻ (20%), γ (28%) | 0.81 (0.233) | 103 | 3 (0.8) | SPECT | Theranostics |
| Holomium-166 (166Ho) | 26.8 h | β⁻ (50.5%), γ (6.7%) | 1.84 (0.665) | 81 | 8.7 (3) | SPECT/MRI | Theranostics |
| Ytterbium-175 (175Yb) | 4.16 d | β⁻ (86.5%), γ (1.9%) | 470 (0.150) | 133 | 2 (0.6) | SPECT | Theranostics |
| Lutetium -177 (177Lu) | 6.7 d | β⁻ (78.6%), γ (11%) | 497 (0.134) | 208 | 2.2 (0.6) | SPECT | Theranostics |
| Rhenium-186 (186Re) | 3.72 d | β⁻ (70%), γ (9.4%) | 1.07 (0.323) | 137.2 | 4.5 (1.5) | SPECT | Theranostics |
| Rhenium-188 (186Re) | 16.9 h | β⁻ (71.6%), γ (15%) | 2.22 (0.765) | 155 | 11 (3.5) | SPECT | Theranostics |
Beyond radionuclide choices, the therapeutic efficacy of TARE is critically governed by the radionuclide carrier matrix or microsphere characteristics (size, material/composition, and morphology) as wells as by pre-procedural planning protocols including dosimetry. The size of microsphere delivering radionuclides for TARE is a principal determinant of lodgment depth within the tumor-feeding arteriolar bed, local radiation dose deposition, and the risk of non-target embolization. Oversized spheres occlude proximal feeding vessels and underdose viable tumor periphery, while undersized spheres risk traversing arteriovenous shunts to deposit in pulmonary or gastrointestinal vasculature [8, 9]. Commercially available microspheres currently span a diameter range of 20 to 60 μm in diameter. However, the ideal size distribution for the best therapeutic efficacy remains under investigation. Matrix material composition is also regarded as critical consideration for their biocompatibility, cost-effectiveness, and structural integrity to withstand radiolytic stress.
A general stepwise overview of TARE procedure for HCC is illustrated in Figure 1. Pre-procedural planning protocols including dosimetry have one of the essential steps for successful TARE. 99mTc-MAA has historically served as the standard surrogate for 90Y TARE pre-treatment dosimetry and planning. Recent advances have introduced several classes of next generation surrogate materials. Theranostic microspheres that integrate therapeutic radionuclide loading with intrinsic imaging capabilities offer promising options for precise treatment planning. Multimodal PET, MRI, and CT visible microspheres have also garnered significant attention with their enhanced spatial resolution and quantitative capabilities for three-dimensional patient-specific dose calculations [10]. Biodegradable surrogate materials have further demonstrated favorable biocompatibility, reducing the risks of permanent off-target embolization [11]. Complementing these material advances, AI-based dosimetry approaches are increasingly being integrated with novel surrogate platforms to enable highly personalized radiation delivery. This review systemically examines recent advancements in surrogate materials and pre-treatment dosimetry planning for TARE of HCC. We address the limitations of traditional surrogates and highlight emerging alternative surrogate materials. We further explore advanced voxel-based and AI-driven dosimetry strategies applicable in conjunction with these surrogate materials with the goal of achieving personalized dose prescription, therapeutic outcome optimization, and improved individual patient care in TARE of HCC.
TARE workflow including dosimetry using surrogate materials and 90Y-microspheres.
Currently, 90Y-glass microspheres (TheraSphere), 90Y-resin microspheres (SIR-Spheres), and 166Ho-poly-L-lactic acid (PLLA) microspheres (QuiremSpheres) have been developed for clinical TARE therapy in HCC. Their characteristics are summarized and compared in Table 2.
Commercially available Clinical Therapeutic Microspheres for TARE
| Properties | Type of Radioactive Microspheres/Particles | ||
|---|---|---|---|
| TheraSphere | Sir-Spheres | QuiremSpheres | |
| Radionuclide | 90Y | 90Y | 166Ho |
| Half-life (h) | 64.1 | 64.1 | 26.8 |
| Eβ⁻ (MeV) | 2.28 | 2.28 | 1.84 |
| Eγ (KeV) | No γ emission | No γ emission | 80.6 (6.7%) |
| Matrix Material | Glass | Resin | PLLA |
| Diameter (µm) - Range (Mean) | 20-30 (25) | 20-60 (32) | 15-60 (30) |
| Density (gcm-3) | 3.3 | 1.6 | 1.4 |
| Specific Activity (Bq/microsphere) | 2500 | 50 | 450 |
| Imaging Type | Bremsstrahlung SPECT; 90Y PET | Bremsstrahlung SPECT;90Y-PET | SPECT; MRI |
| Application | Therapy | Therapy | Theranostics |
TheraSphere, neutron-activated 89Y-dopped glass microspheres, was initially granted FDA Humanitarian Device Exemption (HDE) in 1999 and later obtained full Food and Drug Administration (FDA) approval in 2021 for the treatment of unresectable HCC, based on data from the LEGACY study [10, 12]. This formulation shows high specific activity (approximately 2500 Bq/microsphere) and exceptional radionuclide stability. TheraSphere exhibits a narrow size distribution (20-30 μm), demonstrates minimal leaching (less than 0.13% after six weeks in saline) and has a relatively high density of 3.3 gcm-3 [10]. While clinically established for HCC, the complex multi-step production processes yield only 10-20% of microspheres within the desired size range, affecting manufacturing inefficiency.
SIR-Spheres are composed of resin microspheres with a broader size distribution (20–60 μm) and a density of 1.6 gcm-3 [10]. FDA premarket approval (PMA) was issued in 2002 for the treatment of unresectable metastatic liver tumors [13]. These 90Y-resin microspheres are produced by adsorbing 90Y onto their surface through an ion exchange process [10]. The size distribution is relatively high, resulting in heterogeneous distribution in the liver and unpredictable vascular penetration depth, directly compromising dosimetric reproducibility. While SIR-Spheres offer simplified production methods, lower specific activity (approximately 50 Bq/microsphere) of the microspheres require a significantly higher number of microspheres to deliver a therapeutic dose.
QuiremSpheres are 166Ho-PLLA microspheres and only biodegradable option currently in clinical uses. These microspheres received CE mark approval in Europe in 2015 but remain under FDA consideration for clinical use in the United States [14]. Manufacturing method is involving with the dissolving holmium acetylacetonate (165HoAcAc) and PLLA in chloroform, followed by neutron activation to generate 166Ho-PLLA microspheres. The size range of QuiremSpheres in diameter is from 15 to 60 μm and their density is the lowest (1.4 gcm-3) among commercial microspheres. The characteristic dual β and γ emissions of 166Ho and its paramagnetic properties enable multimodal SPECT and MRI imaging capabilities, facilitating enhanced precise treatment planning and distribution assessment [15]. Nevertheless, there are several clinically and operationally relevant limitations. Comparatively shorter half-life (26.8 hours) and lower β energy than 90Y necessitate the administration of higher radionuclide activity quantities to achieve equivalent therapeutic doses, while narrowing the logistical schedule from the production to patient administration. The exclusive nuclear reactor dependency for the production introduces scheduling inflexibility. At the material level, the radiolytic PLLA degradation poses a structural integrity concern.
While the therapeutic microsphere platforms have established the clinical foundation for TARE over two decades, the ultimate success of this approach depends critically on meticulous pre-treatment planning. The therapeutic efficacy of 90Y-TARE remains fundamentally constrained by the adequacy of intratumoral dose distribution, a parameter governed not only by operator-dependent angiographic mapping, but more critically, by the extent and spatial heterogeneity of tumor perfusion. Emerging dosimetric analyses from high-volume specialized centers have exposed a critical failure mode: incomplete 90Y dose coverage of the tumor volume is the primary driver of treatment failure, with 2-year local control rates falling below 10% in patients with hepatic metastases who receive suboptimal dosimetry [16, 17]. Because dose deposition uniformity is inherently tied to microvascular perfusion architecture, reliable pre-treatment dosimetric prediction remains a major unsolved challenge. Here the global standard ⁹⁹ᵐTc-MAA and ⁹⁹ᵐTc-labeled alternative surrogates are summarized.
99mTc-MAA is widely used as a standard surrogate material for pre-treatment imaging in ⁹⁰Y-TARE. This radiopharmaceutical facilitates dosimetry planning by simulating the anticipated biodistribution of therapeutic ⁹⁰Y microspheres, enabling assessment of tumor targeting efficiency, evaluation of hepatic perfusion patterns, and identification of potential non-target embolization risks. 99mTc-MAA consists of aggregated albumin particles, with over 90% of the particles ranging between 10 and 90 µm in size (mean diameter: 15 µm), though some particles can reach 150 µm [18]. The physical half-life is approximately 6 hours, and its gamma radiation at 140 keV is ideal for planner scintigraphy or SPECT imaging (Figure 2A). Pre-treatment imaging with 99mTc-MAA provides valuable insights into tumor targeting, extrahepatic deposition, and LSF estimation to prevent radiation-induced pneumonitis caused by hepatopulmonary shunting [19]. 99mTc-MAA’s ease of availability, cost-effectiveness, and compatibility with SPECT/CT imaging have established it as the standard surrogate material for 90Y-TARE.
Intrahepatic distribution differences between 99mTc-MAA and 90Y following hepatic artery administration [18]. (A) 99mTc-MAA imaging predicts the therapeutic distribution of 90Y microspheres. (B) Segmentations on contrast-enhanced CT images (top row, a) are co-registered with corresponding pre-treatment 99mTc-MAA SPECT (middle row, b) and post-treatment 90Y SPECT (bottom row, c) images following activity injection into the right hepatic artery. Notable differences in intrahepatic activity distribution are observed between the 99mTc-MAA and 90Y images within the same segmented regions. (C) Right-lobe radioembolization in a 36-year-old patient with colorectal liver metastases. Pre-treatment 99mTc-MAA SPECT (a) and post-treatment 90Y SPECT (b) demonstrate marked discrepancies in microsphere distribution. Digital subtraction angiography (DSA) confirms identical catheter positioning in the right hepatic artery during both procedures (c, d), with coil embolization of the gastroduodenal, right gastric, and supraduodenal arteries. (D) Left-lobe treatment in a 72-year-old patient with uveal melanoma liver metastases. SPECT imaging shows significant differences between pre-treatment 99mTc-MAA (a) and post-treatment 90Y (b) activity distributions, especially in the caudate lobe. DSA reveals variation in catheter tip positioning between injections: during 99mTc-MAA administration (c), the catheter was placed distal to a key side branch, while during 90Y administration (d), it was positioned proximally, likely altering perfusion to the caudate lobe. Adapted with permission from [18], Copyright © 2013 Society of Nuclear Medicine and Molecular Imaging, Inc.
Despite its widespread use, 99mTc-MAA exhibits notable discrepancies in biodistribution compared with 90Y microspheres, primarily due to the differences in particle size, density, vascular hemodynamics, and catheter positioning. These differences can result in suboptimal tumor targeting, unintended radiation to healthy tissues, and inaccurate estimations of extrahepatic shunting. Several studies have highlighted this mismatch; for example, Knesaurek et al. evaluated the reliability of 99mTc-MAA SPECT/CT imaging quantitatively to predict the intrahepatic distribution of 90Y resin microspheres in 20 liver cancer patients [20]. The authors concluded that exclusive reliance on 99mTc-MAA imaging as a predictive surrogate for intra-hepatic distribution of 90Y microspheres can result in systemically discordant dosimetric estimates. Inconsistent and often suboptimal correlation between the two distributions has been observed across patients. Wondergem et al. further evaluated the predictive accuracy of 99mTc-MAA SPECT for 90Y resin microspheres TARE [18]. The results revealed more than 68% of liver segments exhibited discrepancies greater than 10%, as shown in Figure 2. In a related study, Riveira-Martin et al. reported a meaningful correlation between pre-therapy 99mTc-MAA SPECT/CT and post-therapy 90Y bSPECT/CT dose metrices, supporting its potential role in TARE [21]. However, 99mTc-MAA consistently overestimated tumor absorbed dose by ~ 26% and showed mismatches in 90Y microspheres distribution (Figure 3A) and DVH analyses (Figure 3B). These discrepancies impacted dose prediction of tumoral and non-tumoral liver and were attributed to factors such as heterogenous tumor perfusion, necrotic regions, prior embolization, and arteriovenous shunting. These studies delineate the limitations of 99mTc-MAA as a predictive tool and emphasize the need for more accurate imaging surrogates capable of individualized treatment planning. In response, alternative tracers including ⁹⁹ᵐTc-labeled human serum albumin (HSA) and sulfur colloid, have been investigated as surrogate candidates.
(A) Comparison of pre-therapy 99mTc-MAA SPECT/CT and post-therapy ⁹⁰Y bSPECT/CT images. The top row (a-c) shows an example where simulation and therapy imaging exhibit good spatial agreement, while the bottom row (d-e) illustrates a case with clear mismatch between 99mTc-MAA and ⁹⁰Y microsphere distributions. The tumor region (blue) and perfused liver lobe (green) are highlighted in both sets of images. (B) Dose–volume histograms (DVHs) for two HCC patients with a single lesion showing all VOIs (TL, NTLt, NTLw), illustrate a case with good visual agreement on SPECT (left) and a case with poor visual match (right). Adapted with permission from [21], Copyright © 2023 Springer Nature.
99mTc-labeled HSA is an emerging alternative to 99mTc-MAA, designed to produce particles between 20 and 50 µm that closely mimic the size and flow characteristics of 90Y microspheres [22]. The structure of 99mTc-labeled HSA is characterized by the coordination of a 99mTc center to specific functional groups within the large, single-chain HSA protein. The improved stability and biocompatibility of HSA particles in physiological conditions compared to 99mTc-MAA enhances their reliability during pre-treatment angiographic procedures and SPECT imaging. HSA-based tracers not only improve the accuracy of 90Y microsphere distribution predictions but also show potential in dual-tracer imaging. Grosser et al. compared the pharmacokinetics and liver–lung shunt (LLS) estimation of 99mTc-MAA and 99mTc-HSA in pre-treatment planning of TARE involving colorectal cancer patients and found similar liver and lung uptake at initial time points [23]. However, while 99mTc-MAA exhibited relatively rapid degradation over time, resulting in increased lung uptake and an overestimation of LLS at later imaging time points, 99mTc-HSA demonstrated greater in vivo stability, with consistent biodistribution and minimal changes in LLS up to 24 hours post-injection. Authors concluded that 99mTc-HSA is a more reliable and stable alternative compared to MAA for accurate LLS estimation in pre-treatment dosimetry. Furthermore, this approach augments the resolution of treatment planning and guides in detecting subtle shunting patterns that could be missed by 99mTc-MAA alone. The limited commercial availability, non-standardized radiolabeling protocols, and inadequate validation of safety and efficacy have limited the widespread clinical adoption of 99mTc-labeled HSA, particularly in anatomically challenging patients with complex vascular anatomy or significant arteriovenous shunting [24].
99mTc-labeled sulfur colloid is another alternative to 99mTc-MAA that has gained attention, especially for simultaneous dual-tracer hepatic-imaging strategy [25]. Sulfur colloid is an inorganic colloidal dispersion synthesized through acid-precipitated heptasulfide which is structurally distinct from protein-based surrogates such as HSA or MAA. Technetium (99mTc) is physically entrapped within a sulfur matrix, and the synthesis proceeds through the reaction of sodium thiosulfate (Na2S2O3) and a strong acid such as HCl in the presence of pertechnetate (99mTcO4-). The size of sulfur colloid particles ranges from 0.1 to 1.0 µm, smaller than 99mTc-MAA particles. Colloidal particles undergo phagocytic clearance by liver, spleen, and bone marrow rapidly which provides complementary insights into vascular perfusion and embolization patterns [26]. 99mTc-labeled sulfur colloid is used to spatially differentiate perfusion patterns of tumor and non-tumor regions. It is especially utilized for complicated cases that showed marked intratumoral vascular heterogeneity arising from arterial neovascularization and extrahepatic shunting. Lam et al. performed 99mTc-MAA and 99mTc-sulfur colloid dual-tracer SPECT fusion imaging for physiology-based dosimetry in a patient with colorectal liver metastases [27]. In this study, 99mTc-MAA simulated 90Y activity distribution whereas 99mTc-sulfur colloid assessed liver function and perfusion. The absorbed doses to tumors (DT) and functional liver (DFL) were computed by fusing these images. DFL was correlated strongly with liver toxicity while DT was significantly associated with tumor response and survival. Patients receiving DT >55 Gy showed longer survival, highlighting the reliability of dual-tracer approach for personalized treatment planning. Sulfur colloids face several challenges such as translational constraints in production scalability and the requirement of specialized imaging protocols, which limit their routine clinical application.
The radioactive microspheres incorporating theranostic radionuclides, as mentioned in Table 3, demonstrate significant potential for the development of multifunctional TARE surrogate materials. Compared to the conventional workflows using two different radionuclides, these theranostics radioactive microspheres exploit both therapeutic beta emissions and gamma emissions for simultaneous imaging. This strategy facilitates precise tumor targeting, real-time dosimetry, and personalized treatment planning.
Theranostic Radioactive Microspheres loaded with Biodegradable and Non-degradable Materials
| Radionuclide | Microspheres/Particles Materials | Degradability | Particles Size (µm) | Infusion Route | Application | Pre-treatment Imaging | References |
|---|---|---|---|---|---|---|---|
166Ho | Alginate | Biodegradable | 159 ± 19 | Intra-arterial | Pre-clinical TARE in Liver Cancers | MRI, SPECT | [28] |
| PLLA | Biodegradable | 30 ± 5 | Intra-arterial | Pre-clinical and Clinical TARE in Liver Cancer | MRI, SPECT | [14, 15, 29-38] | |
| PLLA (QuiremScout™) | Biodegradable | 30 ± 5 | Intra-arterial | Clinical Scout Dose/ Treatment Planning | MRI, SPECT | [36] | |
| Biorex™ 70 resin | Non-degradable | 30–100 | Intra-arterial | Pre-clinical TARE | MRI, SPECT | [31] | |
188Re | HSA, PLA, collagen, PMMA | Biodegradable & non-degradable | 10–150 | Intra-arterial | Clinical TARE in HCC | SPECT | [39, 40] |
| Starch-based microparticles | Biodegradable | 10–100 | Intra-arterial | Preclinical TARE in HCC | SPECT | [41] | |
| Lipiodol | Non-degradable | NA | Intra-arterial | Clinical TARE in HCC | SPECT | [42, 43] | |
| PLLA microspheres | Biodegradable | 13–48 | Intravenous/ Intra-arterial | Preclinical TARE in HCC | SPECT | [44, 45] | |
153Sm | Amberlite IR-120 resin | Non-degradable | 20–40 | Intra-arterial | Preclinical TARE in HCC | SPECT | [46] |
| Acrylic microspheres | Non-degradable | 35 | Intra-arterial | Preclinical TARE in HCC | SPECT | [47] | |
| PLLA microspheres | Biodegradable | ~35 | Intra-arterial | Preclinical TARE in HCC | SPECT | [48] | |
| Polystyrene microspheres | Non-degradable | ~33 | Intra-arterial | Preclinical TARE in HCC | SPECT | [49] | |
| PHBV microspheres | Non-degradable | ~30 | Intra-arterial | Preclinical TARE in HCC | SPECT | [50] | |
| Polymethacrylate microspheres | Non-degradable | ~29 | Intra-arterial | Preclinical TARE in HCC | SPECT | [51] | |
| 131I | Gelatin Microspheres | Biodegradable | 50-70 | Intratumoral | Local Radionuclide Therapy in HCC | SPECT | [52] [53] |
| Lipiodol | Non-degradable | NA | Intra-arterial | Clinical TARE in HCC | SPECT | [54] | |
| Chitosan Hydrogels | Biodegradable | 100–120 | Intra-arterial | Preclinical TARE in HCC | SPECT | [55] | |
| Chitosan-Collagen Composite | Biodegradable | 10–15 | Intra-arterial | Preclinical TARE in HCC | SPECT | [56] | |
| Silk Fibroin Microspheres | Biodegradable | 11 | Intra-arterial | Preclinical TARE in HCC | SPECT | [57] | |
| 177Lu | Chitosan | Biodegradable | 36.5±5.3 | Intra-arterial | Preclinical TARE in HCC | SPECT | [58] |
| Polydopamine + silica | Non-degradable | ~25 | Intra-arterial | Preclinical TARE in HCC | SPECT | [59] | |
| Alginate | Biodegradable | 2-40 | Intra-arterial | Preclinical TARE in HCC | SPECT | [60] | |
| PLGA | Biodegradable | 25 | Intra-arterial | Preclinical TARE in HCC | SPECT | [61] | |
| Chitosan + Polydopamine + MgO | Biodegradable | 20–30 | Intra-arterial | Preclinical TARE in HCC | SPECT | [62] | |
| 175Yb | PLLA | Biodegradable | 20–40 | Intra-arterial | Preclinical TARE in HCC | SPECT | [63] |
| 142Pr | Rare-earth aluminosilicate glass | Non-degradable | Not confirmed | Intra-arterial | Brachytherapy for hepatic tumors | SPECT | [64] |
166Ho-labeled microspheres represent advanced theranostic agents, combining therapeutic beta emissions with gamma rays (81 keV, 6.7%) suitable for SPECT imaging, enabling simultaneous treatment delivery and real-time dosimetry assessment [31, 33]. 166Ho-loaded microspheres, first introduced for TARE by Nijsen et al., have since been validated through multiple preclinical studies demonstrating their safety, low toxicity, and therapeutic efficacy [65]. The paramagnetic properties of 166Ho allow for MRI-based 3D mapping of microsphere distribution, significantly enhancing treatment planning through MRI-guided dosimetry [15, 29]. Typically, 166Ho is incorporated into poly(L-lactic acid) (PLLA) microspheres, with a size range of 20–60 µm (Figure 4A) [29, 30, 33]. Yavari et al. reported the synthesis, characterization, and dosimetry evaluation of 166Ho-PLLA microspheres for potential use in TARE therapy [30]. The microspheres are produced by a solvent evaporation of 165Ho-acetylacetonate, followed by neutron activation, and show high in vitro stability and radiochemical purity (>99%). The study demonstrated excellent particle integrity and surface characteristics even after neutron irradiation, as shown in Figure 4B. Dosimetry and biodistribution data in rats confirmed high lung retention (~85% at 72 h), minimal off-target activity, and excellent in vivo stability. Subramanian et al. developed 166Ho-labeled Biorex™ 70 resin microsphere as a cost-effective, indigenously manufactured alternative to commercially available TARE platforms, demonstrating a favorable mean particle size (~68 μm) [31]. Excellent hepatic retention (~95%) with minimal off-target accumulation was demonstrated in rats. Clinical validation in the HEPAR trials have further demonstrated strong dose-response relationship and the safety and efficacy of 166Ho microspheres for personalized dosimetry in TARE therapy [32, 36]. Additionally, the scout dose of 166Ho-PLLA microspheres (QuiremScout™) in pre-treatment imaging ensured accurate dose delivery with minimized discrepancies commonly observed in 99mTc-MAA surrogates [33, 34]. However, the lower specific activity of 166Ho microspheres compared to other commercially available microsphere devices may require higher treatment volumes, underscoring the need of additional clinical data to optimize the safety and efficacy [32, 66].
(A) 166Ho-PLLA microspheres. (B) Scanning electron microscopy images of 166Ho-PLLA microspheres after 1 hr neutron activation, showing preserved morphology post-activation. (C) Biodistribution of 166Ho-PLLA in wild-type male rats at 24, 48, and 72 hours following intravenous injection of 100 μCi, expressed as percentage of injected dose (%ID) (c). Each bar represents the mean ± standard deviation (n = 3). Adapted with permissions from [30], Copyright © 2015 John Wiley and Sons, Ltd. (D) Imaging of a 75-year-old male patient with HCC. Contrast-enhanced T1-weighted MR image showing a washout lesion in the right liver lobe (a). T1-weighted multi-gradient echo image post-166Ho radioembolization with liver (green) and tumor (blue) segmentations (b). Fused image combining the T1-weighted sequence with the calculated dose distribution (c); the grayscale bar represents absorbed dose in Grays. Adapted with permission from[33], Copyright © 2019 Springer Nature.
188Re has been extensively investigated as a theranostic radionuclide for TARE [39, 40, 42, 44, 45]. The suitable gamma emission (155 keV, 15%) of 188Re facilitates precise SPECT imaging for accurate dosimetry and enhanced therapeutic planning [41]. A variety of carrier materials such as lipiodol and biodegradable matrices such as HSA, poly-lactic acid (PLA), starch, and PLLA have been used to formulate 188Re-microspheres with the size ranges from 10 to 100 µm, suitable for effective tumor targeting and selective biodistribution [39-42, 44, 45]. In several preclinical studies and clinical trials, excellent radiolabeling efficiency, in vitro stability, and selective hepatic tumor targeting have been reported with 188Re-microspheres. Delaunay et al. used 188Re-Lipiodol in the Phase 1 Lip-Re I clinical trial and demonstrated favorable biodistribution and selective liver retention (>90%), high tumor uptake, and excellent tumor-to-normal tissue dose ratios. They highlighted the potential of 188Re-Lipiodol as a theranostic agent for TARE in HCC [43]. Similarly, Vega et al. fabricated uniform sized 188Re-PLA microspheres (~40 µm) and demonstrated selective tumor localization, high tumor-to-normal tissue dose ratios, and compatibility with SPECT imaging in HCC rat models. These promising theranostic microspheres need further studies to optimize microsphere formulations for uniform size and validate their efficacy through large-scale clinical trials.
The dual functionality of 153Sm facilitates real-time SPECT imaging via its gamma emission (103 keV, 28% abundance), allowing accurate mapping of microsphere distribution and improving the precision of dose calculation in TARE therapy [46, 47, 49, 51]. The neutron activation of 152Sm provides a scalable and cost-effective production pathway, making 153Sm-microspheres particularly accessible in regions with limited radiopharmaceutical infrastructure. Several microparticles, such as Amberlite resin, polystyrene, polymethacrylate, and others, have been utilized to develop 153Sm-microsphere formulations [46, 49, 51]. However, polymers like acrylic, PLLA, and polyhydroxybutyrate-co-3-hydroxyvalerate (PHBV) offer enhanced biocompatibility and significantly reduce long-term embolic risks through their biodegradability [47, 48, 50]. The typical size range of these microspheres is presented in Table 3. In a study, Wong et al. developed 153Sm-acrylic microspheres (~35 µm) and demonstrated high radionuclide retention and excellent labeling efficiency, making them a safer and biocompatible alternative to 90Y-microspheres for TARE [47]. Alregib et al. reported the production of 153Sm-PHBV microspheres (~30 µm) co-loaded with doxorubicin for chemo-radioembolization. These 153Sm-microspheres demonstrated high radionuclide retention and dual cytotoxic effects for the treatment of advanced HCC [50]. The activation of 152Sm to 153Sm requires nuclear reactors, limiting the widespread adoption of 153Sm microspheres for clinical TARE therapy.
131I-labeled Lipiodol gained significant acceptance in the past for the treatment of HCC, particularly in patients with portal vein thrombosis due to their selective tumor accumulation [54, 67, 68]. The favorable gamma emissions profile (364 keV, 81%) of 131I further supports developing novel theranostic microspheres using different biodegradable materials, such as chitosan, silk fibroin, and chitosan-collagen composites [53, 55-57]. The size range of 131I-labeled biodegradable microspheres is presented in Table 3. Several preclinical studies have evaluated the potential of these microspheres for selective tumor embolization, enhanced biodistribution, and natural degradation to minimize long-term embolic risks. For instance, Hwang et al. demonstrated that 131I-labeled chitosan hydrogels (100–120 µm) effectively targeted hepatic tumors and acheived significant tumor growth suppression and minimal extrahepatic deposition in rodent models [55]. In another study, Wu et al. synthesized 131I-labeled silk fibroin microspheres (SFM) around 11 µm diameters with optimal radiolabeling efficiency and demonstrated excellent biodistribution, biocompatibility, and tumor inhibitory effects in rat models [57]. Figure 5 illustrates the stepwise synthesis process, characterization, and in vivo preclinical SPECT/CT imaging performance of SFM and the confirmation of their effective embolization and targeted radiation delivery in rat HCC. Challenges such as dosimetry optimization, off-target effects, and large-scale validation remain to be addressed to enhance their clinical utility.
Development, characterization, and in vivo imaging of 131I-labeled silk fibroin microspheres (SFMs) for TARE in a rat HCC model. (A) Schematic workflow of the synthesis and labeling process: extraction of silk fibroin from Bombyx mori cocoons (a); preparation of SFMs via emulsification and genipin crosslinking (b); radiolabeling of SFMs using the chloramine-T method to yield 131I-SFMs (c); chemical reaction mechanism of iodination on tyrosine residues (d). (B) Physicochemical and morphological characterization: FTIR (a) and XRD spectra (b) of extracted silk fibroin confirming secondary structure; amino acid composition revealing 10.03% tyrosine content (c); optical microscopy of air-dried and swollen SFMs (d); particle size distribution showing ~11 μm diameter (e); SEM confirming spherical morphology (f); suspension stability of SFMs (g); SEM images over 8 weeks showing biodegradation in rat serum (h). (C) In vivo SPECT/CT imaging comparing 131I-NaI and 131I-SFMs biodistribution post transarterial administration. 131I-NaI shows rapid systemic spread and thyroid uptake (2D and 3D views). In contrast, 131I-SFMs demonstrate persistent hepatic retention and localized signal up to 21 days, confirming stable embolization and targeted delivery to liver tumors. Adapted with permission from [57], Copyright © 2022 American Chemical Society.
177Lu-labeled radiotracers have been successfully utilized in the treatment of neuroendocrine tumors and prostate cancers due to their low energetic β-particles (497 keV) and optimal γ-emission (113 and 208 keV) for SPECT imaging-based precise dosimetry and treatment planning [62, 69, 70]. Leveraging this success, various surrogate materials such as chitosan, PLGA, polydopamine (PDA), and alginate are now being investigated for the development of 177Lu-labeled microspheres for preclinical TARE applications [58-62]. These 177Lu-labeled microspheres are often engineered to a range of 20–60 µm, ensuring optimal embolization and selective delivery within tumor vasculature, thus minimizing the risk of leakage and non-target embolization. Several preclinical studies have demonstrated their efficacy and safety in HCC models. For instance, Jin et al. developed 177Lu-labeled PLGA-coated silica microspheres (177Lu-MS@PLGA) by applying a simple PLGA coating over 177Lu-labeled hollow mesoporous silica particles, which demonstrated high radiolabeling efficiency, exceptional in vitro and in vivo radiochemical stability and minimal off-target leakage (Figure 6) [61]. 177Lu-SPECT/CT of rabbit further demonstrated sustained tumor retention, low systemic distribution, and significant tumor growth inhibition. Recently, Wu et al. produced multifunctional PDA-coated 177Lu-microspheres that provide both TARE and photothermal therapy. The 177Lu-SPECT imaging showed precise microspheres localization and enhanced therapeutic effects [59]. The results from these studies collectively highlight the potential of 177Lu-labeled microspheres as a safe, imageable, and highly effective theranostic platform for TARE. The high production cost and limited availability of 177Lu-labeled microspheres currently constrain its broad clinical adoption. Additional optimization in microsphere fabrication and large-scale clinical validation is crucial to firmly establishing its clinical application.
(A) Fabrication of PLGA-coated 177Lu-labeled hollow mesoporous silica microspheres (177Lu-MS@PLGA) using PLGA coating method. (B) Scanning electron microscopy image of PLGA-coated 176Lu-MS@PLGA. (C) MicroSPECT/CT images of HepG2 tumor-bearing mice demonstrate intratumoral retention of 177Lu-MS@PLGA. (D) Digital subtraction angiography (DSA) images obtained before and after intra-arterial embolization highlights the embolization site (yellow box). (E) Serial enhanced CT scans of VX2 liver tumors in three treatment groups; G1: PBS (control), G2: non-radioactive MS@PLGA, and G3: 177Lu-MS@PLGA reveal substantial tumor growth suppression in G3. (F) Tumor volume quantification over 14 days shows significantly greater inhibition in the 177Lu-MS@PLGA group compared to controls. Adapted with permission from [61], Copyright © 2024 American Chemical Society.
142Pr has shown great potential for theranostic TARE applications due to its beta particles (2.162 MeV) and gamma photons (1.575 MeV, 3.7%,) emissions [64, 71]. 142Pr-labeled microspheres are produced through neutron activation of 141Pr embedded within rare-earth aluminosilicate glass [64]. The favorable density of 142Pr-labeled microspheres (~4 g/cm³) enables successful embolization and effective radiation delivery [64, 71]. 142Pr-microspheres offer higher biological effective doses (BEDs), particularly for aggressive tumors when compared to 90Y. The dose distributions are comparable, and the therapeutic delivery is faster due to their shorter half-life (19.12 hours) [64]. Further preclinical research and clinical validation are essential in expanding the efficacy and accessibility of 142Pr-microspheres for TARE therapies.
Previously applied for bone pain palliation and rheumatoid arthritis, 175Yb-labeled microspheres have been recently proposed for TARE as a promising and innovative approach to treat unresectable HCC [72-74]. The favorable half-life (4.2 days) and excellent decay characteristics such as β-particles (470 keV) and γ-emissions (133 keV, 282 keV, and 396 keV) of 175Yb are well suited for simultaneous imaging and effective therapy [72]. In a study, Jamre et al. demonstrated the fabrication and radiolabeling of biodegradable 175Yb-PLLA microspheres (20–40 μm) via neutron activation where they obtained high radiochemical purity and exceptional specific activity [63]. Preclinical studies in mice displayed complete tumoral retention of radioactivity for 48 hours, subsequently suppressed tumor growth from day 4 post-injection and showed significant tumor necrosis at day 12 post-injection. Imaging data showed significant tumor-specific uptake with low systemic distribution, highlighting their potential for intra-tumoral radiotherapy of HCC [63]. Further dosimetry studies and clinical investigations of ¹⁷⁵Yb microspheres can lead to a new treatment option for TARE therapy.
The concept of scout-dose administration using bioidentical microspheres, such as resin-based 90Y (scout90Y) and 166Ho-PLLA (QuiremScout™), has emerged as a more accurate alternative to traditional surrogates like 99mTc-MAA for predicting therapeutic microsphere distribution [34, 36, 75]. Unlike 99mTc-MAA, these scout agents share identical physical and embolic properties with their therapeutic counterparts. Kokabi et al., demonstrated that resin-based 90Y scout doses (mean administered activity of 560 MBq) provides strong correlation with therapeutic biodistribution, particularly in non-segmental treatments where 99mTc-MAA is known to be less reliable [75]. Similarly, 166Ho scout microspheres allowed dual-modality imaging (SPECT and MRI) and providing enhanced visualization and precision dosimetry. Radosa et al., demonstrated that a pre-therapy scout dose (~250 MBq) accurately predicted therapeutic distribution by MRI-based real-time visualization and personalized dose optimization prior to treatment (Figure 4D) [33]. In a similar study, Smits et al. reported strong correlation between 166Ho-PLLA scout and therapeutic dose distributions compared to 99mTc-MAA with narrower 95% limits of agreement for lesion absorbed dose (-90.3 to 105.3 Gy vs. -164.1 to 197.0 Gy) [36]. As illustrated in Figure 7, 166Ho-scout closely matched with the distribution of therapeutic microspheres (166Ho-Therapy), whereas 99mTc-MAA showed a clear discrepancy in SPECT-CT images. Clinically, this improved predictive accuracy with 166Ho-scout has critical implications for the treatment planning.
Comparison of predicted and delivered microsphere distributions using conventional (99mTc-MAA) and bioidentical surrogates (166Ho-scout). (A) Segmentation of liver and tumor volumes overlaid on FDG-PET and co-registered SPECT images acquired with 99mTc-MAA, 166Ho-scout, and post-therapy 166Ho. The additional 1 cm margin illustrates dose coverage regions for comparison across modalities. (B) Representative case demonstrating a clear mismatch between 99mTc-MAA and the 166Ho-therapeutic dose distribution. Despite identical catheter positioning (top row), SPECT-CT images (middle and bottom rows) show that 166Ho-scout closely mimics the therapeutic distribution, while 99mTc-MAA deviates substantially. Adapted with permission from [36], 2020 Springer Nature.
Non-degradable surrogate microspheres pose limitations for repeated TARE procedures due to their permanent embolic effect and potential to obstruct future treatment. While ⁹⁹ᵐTc-MAA is the current clinical standard surrogate for both resin and glass microsphere-based TARE, it exhibits limited correlation with actual microsphere distribution. To overcome these challenges, biodegradable surrogate microspheres have been explored as alternative surrogates for pre-treatment planning [76-78]. Ideally, these microspheres should exhibit biocompatibility, biodegradability, and physiochemical properties including size, shape, and density-comparable to the therapeutic microspheres, to better replicate their intrahepatic distribution. The transient embolic effect of biodegradable microspheres facilitates vascular restoration, thereby enabling repeated treatment cycles without impairing future TARE procedures [79]. Additionally, their degradation into non-toxic byproducts minimizes the risk of ectopic embolization. Several natural and synthetic polymers have been employed to develop such biodegradable microspheres for both preclinical and clinical TARE applications (Figure 8) [22, 56, 62, 80].
Degradation mechanisms of biodegradable surrogate microspheres for radioembolization and drug delivery. Schematics of representative biodegradable polymers that can be used for surrogate microspheres and their dominant degradation mechanisms. Synthetic PLLA and PLGA undergo bulk hydrolytic ester bond cleavage with autocatalytic acceleration due to acidic byproducts. The tunable degradation is over weeks to months depending on composition and crystallinity. Polysaccharides (chitosan, alginate, starch) are primarily degraded via enzymatic glycosidic bond cleavage or ionic crosslink dissociation. Chitosan exhibits lysozyme- and pH-responsive degradation, alginate undergoes Ca²⁺ crosslink exchange and network destabilization, and starch is rapidly cleaved by α-amylase, resulting in transient embolic behavior. Protein-based materials (gelatin, human serum albumin) degrade predominantly through proteolytic enzymatic pathways, with kinetics modulated by crosslink density and local inflammatory milieu. Together, these degradation mechanisms govern in vivo residence time, embolic stability, and clearance kinetics, which are critical parameters for designing next-generation biodegradable surrogate microspheres in TARE.
Poly(L-lactic acid) (PLLA) is a biocompatible and biodegradable polymer extensively used for the synthesis of biodegradable microspheres labeled with various radionuclides, including 166Ho, 186Re, 153Sm and 175Yb for TARE applications [31, 33, 44, 63, 65]. PLLA degrades into non-toxic lactic acid byproducts via hydrolysis, ensuring safe clearance from the body, reducing long-term embolic risks and systemic toxicity, and enhancing its safety profile as a promising alternative to non-degradable microspheres [29]. Once lodged in the capillaries, polymer chains in PLLA microspheres slowly break down into smaller polyester fragments absorbed and recycled as lactic acid, a process taking up to 3 to 6 months at 37°C. Initial spherical morphology is maintained through the therapeutic window for less than 5 days. Progressive hydrolytic fragmentation reduces intact sphere diameter over weeks, with complete fragmentation into submicron lactic acid oligomers by 3~6 months, restoring capillary patency [81, 82]. Several preclinical and clinical studies have shown that PLLA microspheres labeled with 166Ho effectively accumulate in liver tumors with minimal deposition in non-target organs [30, 31, 33, 35]. Yavari et al. validated the in vivo stability of 166Ho-PLLA microspheres in Wistar rats, demonstrating their radioactive purity and effective tumor targeting. Jamre et al. prepared biodegradable PLLA microspheres loaded with 188Re sulfide colloidal nanoparticles (188Re-SC-PLLA) demonstrating excellent in vitro stability and sustained localization in mouse models, highlighting their potential as effective agents for radioembolization of liver tumors [44].
Poly(lactic-co-glycolic acid) (PLGA) is a well-established synthetic biodegradable polymer used extensively in drug delivery and medical implants due to its FDA-approved safety profile and ability to degrade into non-toxic byproducts (lactic acid and glycolic acid), which are naturally metabolized by the body [83-85]. PLGA is an ideal candidate for fabricating radioactive microspheres due to its versatility, biocompatibility, and tunable degradation rates. Several preclinical and clinical studies have been performed that exhibit the potential of radiolabeled PLGA microspheres for tumor-specific radioembolization [61, 85]. For example, Shukla et al. sythesized188Re-DMSA loaded in PLGA microspheres, achieving high radiolabeling efficiency (>97%) and radiochemical stability [85]. Recently, Jin et al. produced 177Lu-labeled PLGA-coated microspheres (177Lu-MS@PLGA) with a mean diameter of ~42.6 μm. These PLGA coated microspheres showed enhanced radiochemical stability due to minimal leakage of 177Lu in biological environments, thus improving tumor retention (Figure 6) [61]. Furthermore, the PLGA allows the microspheres to degrade into non-toxic byproducts (CO₂ and water), offering excellent biosafety for radioembolization therapy. The favorable characteristics of PLGA microspheres such as size, morphology, degradation kinetics and the ability to encapsulate and release radionuclides in a controlled manner makes them superior and promising biodegradable surrogate for effective radioembolization therapy.
Chitosan is a positively charged natural polysaccharide derived from the deacetylated chitin [58]. Excellent biocompatibility, biodegradability, and low toxicity have been demonstrated. Especially, abundant amine and hydroxyl functional groups of chitosan facilitate various radiolabeling with radioisotopes such as ¹³¹I, ¹¹¹In, and ¹⁷⁷Lu. Those radioactive chitosan microspheres (Chi-MS) have been proposed for a promising alternative microsphere TARE platform of HCC [55, 56, 58, 62]. ¹³¹I-labeled chitosan microspheres exhibited effective tumor targeting, prolonged hepatic retention, and significant tumor growth inhibition in preclinical rat models [55]. Additionally, ¹³¹I-labeled chitosan-collagen microspheres developed by Pang et al., showed high radiolabeling efficiency along with enhanced biodegradability and suspension stability [56]. Novel approaches incorporating ¹⁷⁷Lu-labeled chitosan microspheres [58] and ¹⁷⁷Lu-polydopamine-coated Chi-MS with magnesium oxide nanoparticles [62] have also been explored. Favorable radiochemical stability, embolization effectiveness, and hypoxia mitigation were well verified. However, the relatively slow degradation rate of chitosan-based microspheres is less suitable for transient embolization of surrogates [62]. The linear polymer structure and solubility constraints in acidic media also pose additional challenges for clinical applications [58].
Gelatin is a fibrous protein derived from the partial hydrolysis of collagen. Its biodegradability, biocompatibility, non-toxicity, hydrophilicity, and non-immunogenicity has been well-proved, and it is widely regarded as a safe material for a broad range of biomedical applications [86, 87]. Given gelatin’s safety feature, gelatin-based microspheres represent a promising platform, and have been explored as a carrier for radionuclides used in TARE of HCC [52, 53]. Ma et al. reported ¹³¹I-labeled gelatin microspheres (¹³¹I-GMSs) designed for TARE. Hepatic artery infused ¹³¹I-GMSs was visualized with SPECT imaging. Localized ¹³¹I-GMSs in the liver with minimal thyroid accumulation and following degradation over 32-48 days were observed, suggesting slow iodine release and in vivo safety [52]. Another preclinical study by Chi et al. demonstrated high therapeutic efficacy of ¹³¹I-GMSs in a nude mouse HCC model, with extended survival rates relative to control (73.3% vs. 13.3%, P < 0.001). SPECT imaging confirmed selective tumor localization of ¹³¹I-GMSs with minimal off-target accumulation while microspheres remained in tumor tissue for up to 32 days [53]. Additionally, the degradation rate of gelatin can be controlled through the degree of crosslinking, indicating its strong potential as a degradable surrogates platform for TARE of HCC [88].
Alginate is a polysaccharide derived from brown algae. Its biocompatibility, biodegradability, hydrophilicity, and non-toxicity have been well validated, and widely adopted for a range of biomedical applications [89]. It can form hydrogels upon exposure to divalent or trivalent cations such as calcium or lanthanides, making it an ideal matrix for embolization therapy [87]. Recent advancements have further enhanced their functionality by incorporating radioisotopes such as 166Ho, 177Lu and 68Ga for the potential application in radioembolization therapy. Zielhuis et al. developed 166Ho-loaded alginate microspheres and demonstrated their multimodal imaging capability via MRI and gamma imaging [28]. The intra-arterial injection into the renal artery of a pig successfully embolized the left kidney, demonstrating the feasibility of TARE therapy. Yang et al. developed 177Lu-labeled alginate microspheres for radio-immunotherapy in HCC using mouse and rabbit models. In murine model, intratumoral injection of 2 µm microspheres with anti-PD-L1 immunotherapy inhibited primary tumor growth and suppressed distant tumors by modulating the tumor immune microenvironment. In rabbits, intra-arterial injection of 40 µm microspheres successfully embolized the central auricular artery, demonstrating the potential of these microspheres for TARE therapy [60]. Recently, Gupta et al. fabricated polyethyleneimine (PEI) decorated calcium alginate microspheres and labeled with 68Ga (68Ga-PEI-CAMS) as PET imaging surrogates for potential application in TARE [89]. The microspheres fabricated via a spraying–coagulation method exhibited a uniform spherical shape with an average size of ~17.7 ± 7.4 μm after PEI coating (Figure 9). The in vitro degradation studies confirmed 25–35% mass loss within 10 days under physiological conditions, supporting their biodegradability and safety profile. Favorable radiolabeling efficiency and in vivo stability allowed PET imaging of the microspheres. The promise of alginate-based biodegradable microspheres is suggested as a safer and versatile alternative to non-degradable surrogates for pre-treatment imaging and accurate dosimetry in TARE.
(A) Schematic showing calcium alginate microspheres fabrication process using spray-coagulation method. Adapted with permission from [95], Copyright © 2020 Elsevier Ltd. (B) Optical images of CAMSs (a, 64.2 ± 10.2 μm) and PEI-CAMSs (b, 17.7 ± 7.4 μm); (c) shows corresponding particle size distributions, and (d) illustrates in vitro degradation profiles in 0.9% NaCl and PBS over 10 days, demonstrating up to ~35% mass loss in PBS. (C) Schematic showing surface modification of PEI-CAMSs with ADIBO-NHS followed by radiolabeling with [⁶⁸Ga]Ga-NOTA-N₃ via click chemistry reaction. (D) Preclinical PET images acquired at 0–2 h post-injection showing stable localization of [⁶⁸Ga]Ga-NOTA-PEI-CAMSs at the injection site after intravenous (i.v.) and intramuscular (i.m.) administration in mice, confirming in vivo stability. Adapted with permission from [89], Copyright © 2024 American Chemical Society.
HSA microspheres are one of clinical translatable biodegradable platform with favorable biocompatibility and minimal immunogenicity. Inherent versatile binding sites enable stable radionuclides conjugation [22, 40]. Additionally, their resistance to radiolysis makes them a potentially stable radioactive microsphere. These microspheres conjugated with radionuclides such as 99mTc and 188Re have been extensively studied for a surrogate material of TARE [23, 39]. Wunderlich et al. demonstrated that 188Re-HSA microspheres exhibit high stability in vivo while maintaining tumor-selective accumulation and minimizing systemic exposure [39]. The biodegradable matrix of HSA microspheres enables complete resorption within weeks to months, reducing the long-term risk of embolic complications of ischemia and inflammation compared to non-degradable microspheres. Alrfooh et al. highlighted the biodegradability of HSA microspheres as a safer alternative to permanent microspheres [22]. However, radiolabeling efficiency and radiolabeling stability in vivo is relatively low, limiting their widespread clinical adoption. To address these limitations, various synthesis methods, including oil emulsion and microwave-assisted techniques, have been developed to optimize HSA microsphere production [22].
SBMPs are biodegradable embolic agents with crosslinked start polymers that can undergo enzymatic degradation in vivo. Their established safety combined with cost effectiveness has positioned SBMPs as a promising translatable platform for transarterial embolization [22]. Degradable starch microspheres (DSM), such as EmboCept® S DSM 35/50, are commercially available and primarily used for transient intra-arterial hepatic chemoembolization, reducing post-embolization syndromes. The degradation can occur primarily via enzymatic hydrolysis by serum alpha-amylase within 35-40 minutes [90]. Various SBMPs stooges have explored their labeling with co-radionuclides such as ¹⁸⁸Re and ⁶⁸Ga for theranostic applications [41]. Radiolabeled SBMPs are generally synthesized by oxidizing starch with sodium periodate, followed by the functionalization with polyamine ligand (e.g., cadaverine) for radiometal chelation. Verger et al. reported high-efficient radiolabeled ¹⁸⁸Re- and ⁶⁸Ga-SBMPs using ready-to-use radiolabeling kits. Developed radiolabeled ⁶⁸Ga-SBMPs were delivered into hepatic artery in HCC rat models, and their preferential tumor accumulation was successfully monitored by PET/CT imaging [41]. Future clinical studies are critical in validating the dosimetry, safety, and therapeutic efficacy of radiolabeled SBMPs theranostic surrogate platform for image-guided TARE.
SPECT-based surrogate microspheres have several limitations, including production challenges, inconsistent particle sizes, and non-availability of radioactive microspheres with high-specific-activity. In addition, pre-treatment SPECT imaging with these microspheres suffers from lower spatial resolution compared to PET imaging, limiting the precise dose calculations and detailed biodistribution mapping (Table 4). PET surrogate microspheres, on the other hand offers superior imaging capabilities and effective therapy planning through PET image guided MC dosimetry.
SPECT vs. PET Imaging Characteristics
| Imaging Modalities | Characteristics | |||
|---|---|---|---|---|
| Type of Radiation Used | Imaging Probe | Sensitivity | Spatial Resolution | |
| SPECT | γ-rays | 99mTc, 177Lu, 111In, etc. | 10⁻⁹ to 10⁻¹⁰ M (1–10 nM) | 6-12 mm (Clinical) 1-2 mm (pre-clinical) |
| PET | Positron/Annihilation Photons | 18F, 86Y, 64Cu, 89Zr, etc. | 10⁻¹¹ to 10⁻¹² M (10–100 pM) | 2-5 mm (Clinical) 1-2 mm (pre-clinical) |
Several positron-emitting radionuclides, including fluorine-18 (18F), gallium-68 (68Ga), copper-64 (64Cu), yttrium-86 (86Y), and zirconium-89 (89Zr), have been exploited to develop PET-compatible surrogates for 90Y microspheres [41, 89, 91-94]. Selwyn et al. fabricated 18F-labeled resin microspheres (size range: 20–40 µm) as PET surrogates for 90Y resin microspheres [92]. These microspheres were efficiently radiolabeled and showed high in vitro stability. In vivo rabbit study also demonstrated PET monitoring of favorable 18F-labeled resin microspheres biodistribution. PET imaging provided superior resolution and quantification for accurate dosimetry for treatment planning. Similarly, Avila-Rodriguez et al. developed 86Y-, 89Zr-, and 64Cu-labeled resin microspheres sized with 20–40 µm [91]. Efficient radiolabeling and excellent in vitro stability were demonstrated. PET imaging of the radiolabeled resin microspheres in rats showed sufficient in vivo stability for 86Y and 89Zr microspheres, while 64Cu showed significant leaching. Demonstrated superior resolution and quantification of PET imaging capability with the radiolabeled resin microspheres will permit precise tumor-to-normal tissue ratio assessments and enhanced dosimetry. However, the non-degradable nature of resin microspheres poses challenges with long-term biocompatibility and potential embolic risks. In another approach, Larson et al. fabricated 68Ga-infused silica microspheres using a microfluidic technique. They generated stable and nearly monodisperse (10–50 µm) microspheres with excellent in vitro stability without significant leaching [94]. However, their study was limited due to the lack of in vivo validation and microspheres biodegradability data.
To address the shortcomings of traditional microspheres designs, later studies focused on novel materials and methods to fabricate PET microspheres. 68Ga- and 188Re-labeled SBMP with a mean particle size of 29.65 ± 11.73 µm were developed for both pre-treatment PET imaging and TARE therapy [41]. The in vivo studies of 68Ga-SBMP showed successful intra-arterial administration in a DENA-induced HCC rat model, with >95% localization of 68Ga-SBMP in the liver, particularly in tumors. 68Ga-PET/CT confirmed minimal off-target distribution and no systemic recirculation, demonstrating the stability and potential of 68Ga-SBMP as a PET-compatible microspheres for pre-treatment imaging and personalized dosimetry. Moreover, the biodegradability of SBMP, ease of generator-based 68Ga production and improved spatial resolution and quantitative accuracy of PET imaging position them as promising alternatives to existing surrogate microspheres. In another study, Chambers et al. introduced 18F-labeled ceramic hydroxyapatite microspheres of 20–30 µm with high radiochemical stability [93]. The PET imaging in rats, following intravenous tail vein injection, demonstrated selective hepatic accumulation and biodistribution consistent with 90Y-microspheres. Recently, 68Ga-labeled alginate-based biodegradable PET microspheres developed by Gupta et al. demonstrated excellent properties as a promising surrogate for preoperative imaging in TARE therapy [89]. The biodegradability of alginate, combined with its straightforward click chemistry-based radiolabeling, resulted in excellent radiolabeling efficiency (>99%) and high in vitro radiochemical stability (>92%) in both PBS and human serum. Preclinical PET imaging (Figure 9), further confirmed in vivo stability and biodistribution, supporting their potential application as PET surrogates. However, PET-compatible microspheres have several limitations, including the short half-life of radioisotopes, radionuclide leakage, generation of inconsistent particle size, material degradability, and limited preclinical and clinical data. PET-compatible microspheres and their characteristics have been summarized in Table 5. Additional research should focus on designing PET microspheres with optimal particle size to accurately mimic the behavior of 90Y microspheres. Further, robust preclinical and clinical studies using the transarterial infusion approach are needed to establish their role as imaging surrogates for 90Y in HCC treatment. In addition to these technical limitations, the clinical translation of PET-based surrogate microspheres is influenced by cost and feasibility considerations. Compared to the widely utilized 99mTc-MAA, which is relatively inexpensive, PET radionuclides such as 18F and 68Ga require more advanced and expensive production methods, imaging infrastructures and radiochemistry support, increasing overall procedural costs. While generator-produced 68Ga improves accessibility relative to cyclotron-dependent tracers, their implementation remains limited in resource-constraints settings. PET-based surrogates offer superior spatial resolution and quantitative accuracy; however, their routine clinical application may be restricted to specialized centers or complex cases where high-precision dosimetry is critical. Therefore, PET-compatible microspheres are currently best considered as complementary tools to 99mTc-MAA, with their adoption guided by clinical need, resource availability, and the anticipated benefit in personalized dosimetry.
PET-compatible surrogate particles for 90Y Microspheres
| Radionuclide | Microspheres/ Particles | Degradability | Particles Size (µm) | Administration Route | Application | Imaging Method | Dosimetry Method | References |
|---|---|---|---|---|---|---|---|---|
| 89Zr | Resin | Non-degradable | 20-40 | Intra-arterial | Pre-clinical | PET | PET Image-based voxel dosimetry & MC simulation | [91] |
| 86Y | Resin | Non-degradable | 20-40 | Intra-arterial | Pre-clinical | PET | PET Image-based voxel dosimetry & MC simulation | [91] |
| 18F | Resin | Non-degradable | 20-40 | Intra-arterial | Pre-clinical | PET | PET Image-based voxel dosimetry & MC simulation | [92] |
| Ceramic hydroxyapatite | Non-degradable | 20-50 | Intra-arterial | Pre-clinical | PET | PET Image-based voxel dosimetry & MC simulation | [93] | |
| 68Ga | Starch-based microparticles | Biodegradable | 10-100 | Intra-arterial | Pre-clinical | PET | PET Image-based voxel dosimetry & MC simulation | [41] |
| Silica | Non-degradable | 10-50 | Intra-arterial | Pre-clinical | PET | PET Image-based voxel dosimetry & MC simulation | [94] | |
| PEI-Alginate | Biodegradable | 10-25 | Intravenous/ Intramuscular | Pre-clinical | PET | PET Image-based voxel dosimetry & MC simulation | [89] |
Transmission imaging modalities, such as CT and digital subtraction angiography, are widely used for their high resolution and diagnostic accuracy, often enhanced by radiopaque contrast agents that improve visualization of anatomical structures [96]. This principle has been extended to the development of radiopaque microspheres by incorporating high atomic number materials, such as iodine, tantalum, gold or barium sulfate, into polymeric microspheres [97, 98]. For example, iodine-modified acrylamido-polyvinyl alcohol (PVA-AMPS) microspheres (70-300 μm), such as LC Bead LUMI™ and DC Bead LUMI™ demonstrated excellent radiopacity during embolization procedures and are FDA-approved for use in hypervascular tumors and arteriovenous malformations [99, 100]. Zeng et al. investigated tantalum nanoparticle-loaded alginate microspheres (Ta@CaAlg), which exhibited radiopacity comparable to Iodixanol, a commercial contrast agent [101]. Renal artery embolization in rabbits demonstrated their long-term visibility and efficacy, highlighting their potential for TARE applications. Radiopaque microspheres provide real-time visualization, facilitating precise targeting of hepatic tumors in TARE. Moreover, their imageability allows interventional radiologists to modify the treatment strategy during the TARE procedure using CT imaging, improving the chances of achieving adequate absorbed doses across all tumor regions.
Recently, Eye90 microspheres, developed by ABK Biomedical, have emerged as innovative radiopaque microspheres for embolic therapies for TARE [8, 102-104]. Eye90 microspheres are composed of a proprietary radiopaque glass composition containing high atomic number compounds, designed to closely resemble glass (TheraSphere) microspheres in size (20–30 μm diameter) and density (3.4 g/cm³). The 90Y in Eye90 microspheres is generated through thermal neutron absorption of 89Y embedded within the glass matrix. The radiopacity of Eye90 microspheres enables real-time localization of microspheres using high resolution CT imaging, primarily addressing the limitations of limited spatial resolution associated with 90Y PET and bremsstrahlung SPECT [103]. Henry et al. conducted several phantom studies to establish and validate a quantitative relationship between CT Hounsfield Units and radiopaque microsphere concentration and showed the potential of CT-based dosimetry in 90Y TARE [102, 103]. This group demonstrated superior dose distribution visualization, reduced partial volume effects, and enhanced representation of dose heterogeneity in preclinical rabbit liver models using CT-based dosimetry. In a first-in-human clinical trial, Abraham et al. assessed the safety, therapeutic effectiveness, and imaging capabilities of radiopaque Eye90 microspheres in individuals with unresectable hepatocellular carcinoma, using a dual-syringe system for intraarterial delivery [8]. The results revealed strong agreement between microsphere localization seen on CT and radioactivity patterns observed on SPECT/CT, enabling real-time visualization of tumor targeting. The inherent radiopacity of Eye90 microspheres allowed the detection of heterogeneous dose distributions and highlighted areas of insufficient tumor coverage. The treatment was well-tolerated, and most of the patients exhibited either complete or partial responses at both 90- and 180-day post-treatment. Overall, the study underscored the potential of CT-visible microspheres to enhance precision in 90Y radioembolization and enable future CT-based dosimetry.
MRI-visible microspheres enable high-resolution imaging of microspheres distribution and precise dose measurement without ionizing radiation [105-107]. MRI-visible microspheres are classified into T1-weighted agents (e.g., gadolinium-based compounds) and T2-weighted agents (e.g., superparamagnetic iron oxide nanoparticles; SPIONs). Li et al. fabricated SPIO-labeled yttrium microspheres ranging from 20 to 40 µm in diameter, composed of yttria-alumina-silicate (YAS) glass with 2-20% SPIO. They demonstrated that microspheres with 2% SPIO content exhibit a strong correlation between MR imaging R2* and microsphere concentrations (R² = 1.00, P < .001) [108]. In animal models, their study reported that MR-based dose quantification showed high accuracy, with a strong correlation between R2 values and the infused microspheres dose (ICC = 0.98, P < .001). In a study, Qin et al. designed MRI-visible polymer microspheres by embedding magnetic ferrite nanoclusters (FNs) into a poly(acrylic acid) hydrogel matrix [109]. These microspheres fabricated using a microwave-assisted solvothermal reduction method were ranged in size from 100 to 900 µm. Their study demonstrated that T₂-weighted MRI signals decreased proportionally with increasing microsphere concentration, reflecting strong susceptibility effects. The in vivo experiments confirmed that subcutaneously injected magnetic microspheres in mice remained clearly visible on MR images for up to 28 days. Some researchers have developed polyvinyl alcohol (PVA) hybrid microspheres incorporating gadolinium oxide (Gd₂O₃) and iron oxide (Fe₃O₄) to enable dual T1/T2 MRI imaging [110]. Another approach includes iron oxide-loaded tris-acryl microspheres and holmium-lipiodol-alginate microspheres, which allow visualization across multiple imaging modalities, including MRI and CT [111, 112]. However, the microspheres described above, such as polymer-based and PVA hybrid formulations incorporating Gd₂O₃ and Fe₃O₄ remain in preclinical stages and have not yet been utilized for TARE due to size limitations or incomplete validation of biocompatibility. In contrast, 166Ho-PLLA microspheres have been extensively studied for TARE. Their inherent MR visibility allows for mapping of microspheres distribution and dosimetry via quantitative MRI and SPECT. Various clinical trials, including the HEPAR studies have demonstrated that 166Ho-microspheres enable accurate assessment of intrahepatic microspheres deposition and allow for integrated imaging-therapy workflows using single agent [14, 15, 29, 32, 33, 36, 65]. Among MRI-visible microspheres, both SPIO-labeled microspheres and 166Ho-PLLA microspheres holds strong promise for MRI-guided treatment planning and post-treatment dosimetry in TARE.
99mTc-Nanoparticles composite is emerging as a superior surrogate for 90Y TARE, addressing the limitations of conventional 99mTc-MAA, which often disaggregates in vivo, leading to uneven distribution and potential systemic leakage. [113, 114]. The 99mTc-Nanoparticles composite microspheres developed by Stephens et al. consists of protamine-coated 99mTc-labeled carbon nanoparticles (FibrinLite; 150–350 nm), electrostatically attached to polystyrene sulfonate microspheres (30 µm, 12 µm, and 8 µm), using the same polymer base as clinically used 90Y microspheres. [113]. The radiolabeling method produces highly stable microspheres that retain 99mTc even after extensive washing and in vivo circulation. Scanning electron microscopy has confirmed uniform nanoparticle attachment on the microsphere surface (Figure 10A). In preclinical rabbit models, lung retention of these radiolabeled nanocomposite microspheres ranged from 72.8% (8-µm) to 92.9% (30-µm), compared to only 66.8% for 99mTc-MAA, which also exhibited higher systemic leakage (29%) as shown in Figure 10B. The retention of the microspheres in normal liver was significantly higher (99.2% to 99.8%), whereas in VX2 tumor-bearing livers, it ranged from 98.2% to 99.2%. The tumor uptake following intrahepatic arterial infusion was 32.0%–33.0% of total liver radioactivity, reflecting increased arterial perfusion due to angiogenesis. Moreover, the smaller microspheres (8 µm) provided detailed visualization and tumor targeting due to their ability to reach finer vasculature (Figure 10C), demonstrating their potential for superior dosimetry planning. These findings suggest that radiolabeled nanocomposites are a promising surrogate for therapeutic microspheres, offering improved stability, biodistribution, and imaging precision for more accurate pre-therapy planning in clinical TARE of HCC. However, further preclinical validation, long-term biocompatibility assessments, and clinical trials are needed before widespread clinical adoption.
Characterization and imaging performance of 99mTc-labeled nanoparticle composite microspheres [113]. (A) Scanning electron microscopy (SEM) images showing the surface morphology of radiolabeled microspheres with protamine-coated 99mTc-carbon nanoparticles. (B) Representative SPECT images of normal rabbit lungs 3 hours after intravenous injection of radiolabeled microspheres of different sizes: 30 µm (a), 12 µm (b), and 8 µm (c), and comparison with clinical 99mTc-MAA (d). Microspheres exhibit strong lung retention with decreasing size showing broader distribution, while 99mTc-MAA shows visible kidney uptake indicating leaching. (C) Fused SPECT/CT images (coronal, sagittal, and transaxial views) of a rabbit liver with a VX2 tumor 1 h post-intra-arterial infusion of 8 µm radiolabeled microspheres, highlighting clear localization and definition of the tumor region. Adapted with permission from [113], Copyright © 2019 Taylor & Francis.
The basic concept behind TARE therapy is the dual blood supply in liver, where tumor receives blood predominantly from hepatic artery, while normal liver parenchyma is mainly supplied from portal vein, enabling intra-arterial delivery of radioactive microspheres [11]. This technique facilitates selective and preferential accumulation of microspheres within tumor microvasculature, resulting in highly localized radiation exposure to tumors. The important component of TARE includes dosimetry planning, allowing the estimation of patient-specific absorbed dose that ensures maximum radiation dose to tumors while reducing the exposure to normal liver tissues. The prior studies reported a threshold dose of ~100 Gy was considered sufficient for controlling tumor, while exposure < 30 Gy to normal liver prevent radiation-induced liver disease (RILD) [115, 116]. However, the results from the LEGACY study and the recent clinical trials have proposed the threshold doses according to the treatment methods (segmental vs. lobar) and microsphere types (glass vs. resin) [117]. These studies demonstrate that in radiation segmentectomy, ablative doses often exceed 400 Gy with glass microspheres, while 190-200 Gy is typically recommended for resin microspheres. In contrast, for lobar treatment, the DOSISPHERE-01 trial using glass microspheres showed that glass microspheres can deliver up to 250 Gy to the tumor dose while sparing healthy liver tissue, whereas the tumoricidal dose for resin microspheres is lower typically between 100 Gy and 120 Gy due to the differences in particle characteristics and dosimetry behavior [118]. Dosimetry methodologies in TARE are categorized as pre-treatment (planning) or post-treatment (verification) approaches.
The TARE workflow begins with baseline imaging (contrast-enhanced CT, MRI, or PET/CT) to assess tumor burden followed by mesenteric angiography to precisely map the hepatic arterial anatomy and identify any extrahepatic vessels [11]. Subsequently, intra-arterial administration of surrogate microspheres (predominantly 99mTc-MAA) is performed using angiographic guidance, and planar scintigraphy or SPECT imaging to assess microspheres distribution and enable pre-treatment dosimetry [119]. Pre-treatment imaging and dosimetry provide prior knowledge of absorbed dose and lung shunt fraction estimates for patient-specific tumor targeting during TARE therapy. The threshold dose for normal liver parenchyma is ~ 60 Gy for glass microspheres however, it is ~ 40 Gy only for resin microspheres due to their higher particle number and lower specific activity. [120]. An excessive lung shunt fraction increases the risk of radiation-induced pneumonitis, especially when the lung dose >30 Gy in a single treatment or 50 Gy cumulatively [121]. Post-treatment bremsstrahlung SPECT (bSPECT) or 90Y PET imaging is generally after the administration of therapeutic radioactive microspheres to evaluate post-treatment dose distribution and treatment response. This section summarizes the strengths and limitations of conventional pre-treatment dosimetry methods and highlights the recent advances in patient-specific absorbed dose calculation approaches.
BSA method is a simple and semi-empirical dosimetry approach widely used for resin microspheres, estimates administered activity based on the body surface area of a patient [122, 123]. This method does not require 99mTc-MAA SPECT/CT imaging for treatment planning, making it computationally fast and valuable in clinical settings [122]. However, this method has several limitations such as it does not account for the variations in tumor-to-normal liver (T/N) ratio that potentially results in suboptimal dose distribution. Because this method assumes a fixed relationship between patient size and liver volume, it may lead to overestimation or underestimation of required activity, particularly in large patients with smaller livers, and vice versa [114].
The single-Compartment MIRD model is considered as standard dosimetry method in clinical TARE therapy, particularly when using glass microspheres. However, this MIRD model is based on assumptions that the activity is uniformly distributed in source regions and does not consider macroscopic and microscopic uptake and absorbed dose heterogeneity [122, 124]. The targeted liver is treated as a single homogenous compartment to estimate required activity of therapeutic microspheres. As mentioned above, this method does not account for spatial heterogeneity in microsphere distribution, limits the dosimetry accuracy in patients with variable T/N uptake and may lead to underdosing of tumor or overdosing of normal liver parenchyma [114]. These drawbacks have limited the widespread adoption of this model in clinical settings.
In the Partition model, the liver is divided into multiple compartments (tumor, normal liver, and lung compartments). Because the dosimetry is still based on MIRD schema, it is also commonly referred as multi-compartment MIRD model. Compared to the BSA and single-compartment MIRD models, the PM is more accurate in activity estimation and applicable to both glass and resin microspheres. This method integrates 99mTc-MAA SPECT/CT imaging in treatment planning to incorporate T/N ratios, it provides more accurate and personalized activity estimation, maximizing tumor-absorbed dose (≥205 Gy for glass microspheres) while minimizing radiation exposure to normal liver and lungs [125, 126]. The results from DOSISPHERE-01 trial highlight the benefits of PM when using 99mTc-MAA SPECT/CT. It significantly improved objective response rates (71% vs. 36%, p=0.0074) and overall survival (26.6 months vs. 10.7 months, p=0.0096) in HCC patients compared to standard dosimetry. PM-based personalized dosimetry achieved 96% objective response rate (tumor-absorbed doses ≥205 Gy) compared to only 42% in the standard dosimetry group (tumor-absorbed dose ~120 Gy), confirming that higher tumor doses significantly correlate with improved survival and response rates without increasing treatment-related toxicity [118]. Although PM is more accurate and safer, its application remains limited due to the requirement of high-resolution imaging and time-consuming volume determination steps for precise uptake measurements [11]. Furthermore, PM assumes uniform dose distribution within each compartment; it may not be accurate for highly heterogeneous tumors, leading to suboptimal therapy [119].
Another dosimetry approach called MTPM was formulated to mitigate the above limitations. In MTPM, each tumor is treated as an independent compartment with its own T/N ratio and absorbed dose estimations, accounting for inter-tumor variability in vascularity and microsphere uptake to enhance dose accuracy [114, 125]. This model performs differential dosing in each lesion, ensuring effective radiation dose without non-specific radiation. MTPM integrates effectively with 99mTc-MAA SPECT/CT image-based voxel dosimetry and provides 3D dose distribution maps [125]. Comparative studies between PM and MTPM demonstrated closer alignment of MTPM with advanced 3D voxel-based dosimetry models that is confirming its superior accuracy in dose prediction. When 3D voxel dosimetry is not available, MTPM represents the optimal alternative for personalized dosimetry.
The Local Deposition Model (LDM) and Dose Point Kernel (DPK) convolution Model are the representative voxel-based methods that account for spatial activity distribution providing voxel-level absorbed dose estimation using SPECT/CT imaging data. LDM is assuming that all beta energy from 90Y-microspheres is deposited within the voxel containing the radioactivity. This method enables computationally efficient dose calculations by converting 99mTc-MAA SPECT counts into 90Y activity concentrations with assuming entrapped microsphere in liver tissue. Moran et al. showed that LDM yielded mean tumor absorbed doses 20–30% higher than PM predictions, particularly in patients with multiple tumors [125]. Since LDM does not consider beta particle cross-absorbed dose between adjacent voxels, it underestimates dose in highly perfused regions, limiting its application [114]. The DPK convolution model convolves a precomputed dose point kernel with the cumulative activity distribution from 99mTc-MAA SPECT to determine absorbed dose. In contrast to LDM, the DPK method also incorporates beta-particle cross-absorbed dose between the neighboring voxels, estimating more accurate absorbed dose as demonstrated by Moran et al., where DPK provided ~ 22% higher tumor absorbed compared to PM [125]. Their study also found DPK dosimetry correlated more closely with clinical outcomes than LDM, particularly for tumors with heterogeneous microsphere distribution. Similarly, Kim et al. reported that DPK convolution significantly improved dose estimation for large tumor volumes where cross-irradiation effects are more pronounced [119].
The recent advancement in medical imaging infrastructures and image reconstruction algorithms have facilitated the way for more accurate pre-treatment imaging and dosimetry. Moreover, the accuracy of surrogate-based pre-treatment dosimetry approaches has improved, transitioning from compartmental models to high resolution voxel-based and multimodal techniques (Figure 11). These methodological advancements enable better mapping of heterogenous microsphere distribution and estimation of patient-specific absorbed dose.
Advanced pre-treatment dosimetry workflow in TARE using radiolabeled surrogate microspheres. An integrated framework for patient-specific dosimetry including sequential baseline vascular mapping, surrogate microsphere administration, and pre-treatment imaging, followed by image registration and voxelized density-activity mapping. MRI/CT-based dosimetry, MC radiation transport simulation, AI–assisted analysis, and computational fluid dynamics modeling of microsphere are combined to predict microsphere distribution and absorbed dose, enabling optimized activity prescription and personalized TARE planning.
Leveraging the high spatial resolution of CT, post-treatment imaging using radiopaque microspheres is a promising method for assessing microsphere distribution and estimating absorbed dose in 90Y radioembolization [8, 102, 103]. In contrast to PET and SPECT imaging, which are limited by lower spatial resolution and motion artefacts, CT imaging offers greater detail for evaluating dose heterogeneity. Preclinical studies using imageable microspheres, such as Eye90, have demonstrated strong correlation between microsphere distribution and absorbed dose, validating its potential for post-treatment dose confirmation. For example, in a porcine renal model, micro-CT based activity mapping yielded mean dose within 5.7% of the MC-calculated reference values. Dose-volume metrics such as D70 (the dose delivered to 70% of the target volume) values were shown to strongly correlate with voxel size (R² = 0.90), further underscores the advantage of high-resolution CT imaging for accurate dose distribution [102]. Similarly, a rabbit liver study, utilizing a CT calibration phantom showed strong correlation (R² > 0.999) between Hounsfield units and microsphere concentration, enabling accurate voxelized dose assessment as shown in Figure 12A-B [103]. The mean dose in CT-derived distributions showed greater heterogeneity with a coefficient of variation of 1.99, compared to 1.02 in PET, which highlights the improved precision of CT imaging. Recent clinical studies have continued to validate this dosimetry approach, showing that radiopaque microspheres not only enhance visualization but also improve tumor targeting accuracy when combined with SPECT imaging [8]. In a clinical trial, Abraham et al. demonstrated precise CT-based visualization of microsphere distribution, which correlated with SPECT-based dosimetry. In their study, the administered activity ranged from 0.4 GBq to 9.6 GBq, achieving tumor doses exceeding 250 Gy in some cases, while keeping doses to normal liver tissues safe. Figure 12C demonstrates strong visual correlation between microsphere radiopacity on post-treatment CT and radioactivity on SPECT/CT, confirming accurate tumor targeting. Overall, post-treatment CT imaging provides an effective means to improve spatial resolution, mitigate respiratory motion artifacts, and provide a comprehensive assessment of dose heterogeneity, thereby enhancing visualization of 90Y TARE dosing.
CT-based dosimetry. (A) MC-derived dose-voxel kernels (DVKs) for 90Y. CT-specific DVK with higher spatial resolution shows concentrated dose in the central voxel (a, b). PET-specific DVK with coarser voxel size demonstrates broader, more diffuse dose spread (c, d). Both DVKs are normalized per history in a water-equivalent voxel matrix. (B) Comparison of CT- and PET-based dose distributions in a rabbit liver following administration of radiopaque Eye90 microspheres. CT-based dose distribution (DDCT) overlaid on CT slices, revealing highly heterogeneous and localized hotspots aligned with embolized vasculature (a–c). PET-based dose distribution (DDPET) shows smoothed, lower-resolution dose maps with fewer identifiable hotspots due to partial volume effects and respiratory motion (d–f). Adapted with permission from [103], Copyright © 2022 Springer Nature. (C) Multimodal clinical imaging of 90Y-radioembolization with radiopaque microspheres. Pre-treatment contrast-enhanced CT shows a 4.3-cm tumor in segment 8 (arrowheads; a). Digital subtraction angiography confirming catheter placement (black arrow; b). Post-treatment non-contrast CT confirms radiopaque Eye90 microsphere distribution (white arrow; c). Post-treatment Bremsstrahlung SPECT/CT demonstrates Eye90 microsphere radioactivity within the tumor (outlined by the circular contour) and the treated volume, closely matching the microsphere radiopacity distribution observed on CT in figure 2c (d). Non-contrast CT in follow-up confirms persistent radiopacity in embolized vessels (white arrow; e), supporting potential role as a long-term treatment biomarker (e). Adapted with permission from [8], Copyright © 2024 Elsevier.
MRI-based dosimetry has evolved from a theoretical concept into a clinically viable tool for precise radiation dose estimation in TARE, leveraging the paramagnetic properties of 166Ho- microspheres to enable direct imaging with MRI [15, 29, 127]. The recent clinical trial confirmed the feasibility and potential superiority of MRI-based dosimetry compared to SPECT-based methods [127]. Seevinck et al. first demonstrated MRI-based quantification of 166Ho-PLLA-MS using a DPK convolution method, showing a high correlation (R² = 0.99) with SPECT-based dosimetry [29]. MRI-based dosimetry involves pre-treatment T2-weighted imaging, voxel-wise transverse relaxation quantification for microsphere concentration, and MC modeling for dose map generation [29]. Recently, Roosen et al. introduced intraprocedural MRI-based dosimetry in the EMERITUS-1 clinical trial, enabling dynamic treatment adjustments to optimize tumor coverage, minimize toxicity, and improve administered activity detection by an average of 5.8% [127]. Their study reported a case where 99mTc-MAA SPECT/CT inaccurately showed complete tumor coverage that results in undertreatment of a portion of tumor supplied by an aberrant phrenic artery. MRI-based dosimetry however, identified the underdosed portion precisely and facilitated retreatment using 166Ho TARE, emphasizing the critical advantage of real-time MRI-based dosimetry in identifying perfusion mismatches and optimizing treatment strategies (Figure 13). Because of higher spatial resolution of MRI compared to SPECT, MRI-based dosimetry demonstrated reduced dosimetry uncertainties (5–10% errors), outperforming SPECT-based uncertainties (10–20% errors). MRI-based dosimetry has several advantages including non-ionizing imaging for microspheres localization however, its clinical utilization remains limited due to susceptibility and motion artifacts of MRI and high costs which are highly relevant to emerging MRI-visible agents. Recent advances and future developments in MRI infrastructures and such as hybrid PET/MRI imaging, MRI-compatible injection systems, artefacts-free MR imaging, AI-driven dose calculations, and large-scale clinical trials, could help establish its role in next-generation image-guide TARE.
Intraprocedural MRI-based dosimetry during 166HoTARE. (A) Comparison between pre-treatment 99mTc-SPECT-based dose simulation (a) and intraprocedural MRI-based dose maps acquired after stepwise administration of 166Ho-microspheres (10%, 40%, 70%, and 100% activity) in a patient with breast cancer liver metastases (b-e). The mean tumor dose (Dmean) increases from 6 to 17 Gy however, spatial dose distribution remains largely unchanged, suggesting that increased activity alone may not compensate for suboptimal microsphere deposition. (B) Another case of HCC showing incomplete tumor coverage due to variant vascular anatomy. MRI-based dose maps after each of four sequential administrations of 166Ho-microspheres via the right hepatic artery (a), a portion of the tumor (dashed line) remained undertreated due to vascularization from an aberrant phrenic artery branch (arrow). Pre-treatment 99mTc-SPECT/CT simulation showing predicted microsphere distribution (b). Diffusion-weighted MRI before (c) and 3 months after (d) treatment shows persistent diffusion restriction in the undertreated tumor region (arrow). Digital subtraction angiography visualizing the aberrant vessel supplying the residual tumor; the asterisk indicates the persistent tumor vasculature (e). Post-re-treatment 166Ho-SPECT/CT after catheterization of the aberrant vessel, showing high microsphere uptake in the previously undertreated area (arrow), indicating successful targeting during the second intervention (f). Adapted with permission from [127], Copyright © 2022 Springer Nature.
MC simulation is widely regarded as gold standard in voxel-based dosimetry by explicitly modeling radiation transport and patient-specific tissue heterogeneity using CT-derived phantoms and SPECT-based activity distributions, providing highly accurate absorbed dose estimation in RPT and TARE therapy [128-130]. Despite its advantages in integrating anatomical and functional heterogeneity, studies comparing MC simulation to image-based methods have yielded mixed results, with some showing no significant differences in dose calculations [114]. However, a prior study reported that MC-derived doses were, on average, 25–40% higher than those obtained from standard PM method, reflecting the latter’s tendency to underestimate dose deposition in non-uniform activity regions [125]. d’Andrea et al. highlighted the role of MC simulations for lung dosimetry in 90Y TARE that resulted in ~ 88% improved accuracy in absorbed dose estimation at voxel-level compared to conventional dosimetry methods, underscoring its reliability in reducing uncertainties in lung shunt estimation and improving treatment efficacy (Figure 14) [131]. MC dosimetry method remains computationally intensive and time-consuming, limiting its clinical application. The ongoing efforts to develop GPU-accelerated MC algorithms aim to overcome these limitations.
Comparison of absorbed dose distributions obtained from MC simulations and classical voxel-based methods for a lung shunt (LS) of 20%. From left to right, this figure shows activity biodistribution, followed by the AD distribution maps from MC simulations and several convolution-based approaches (SVOX_L, Lung_296, and Lung_L) for visual comparison. The colors used to depict activity biodistribution are illustrative, indicating a uniform distribution within each region. For Lung_296 and Lung_L, AD distributions exclude the liver region due to the computational choice to crop the activity map to the lungs. AD values are reported in Gy per GBq of administered activity, with Lung_296 represented on a different color scale (0 to 40 Gy/GBq) compared to other methods (0 to 120 Gy/GBq) to ensure visibility of dose values. Adapted with permission from [131], Copyright © 2024 MDPI.
AI and DL have been extensively used in nuclear medicine imaging and RPT dosimetry to enhance accuracy, efficiency, and clinical scalability. MC-based dosimetry method provides highly accurate dose estimates at voxel-level but remains computationally intensive and time-consuming, limiting their routine clinical application. To address this issue, recent studies have demonstrated that AI- and DL-based dosimetry models can approximate MC-level accuracy in dose estimates with substantially reduced computation time [132-134]. Recent studies have demonstrated that AI models can approximate MC-level dose calculations with substantially reduced computation time. Kim et al. develop a DL-based dosimetry framework that estimate dose comparable to MC simulations while significantly reducing computational burden [135]. Ha et al. reported that the DL method capable of predicting voxel-level dose distributions with strong agreement to MC simulations (R2 up to 0.99), while reducing computation time from approximately 4.6 hours to 2.6 minutes [136]. Importantly, their model demonstrated the ability to generalize across radionuclides without radionuclides-specific training data, addressing a major limitation of prior AI-based dosimetry approaches. Furthermore, Ahn et al. showed that DL model can accurately predict patient-specific dose distribution directly from anatomical inputs, outperforming conventional knowledge-based planning approaches significantly reducing planning time [137]. In the context of 90Y-TARE, these capabilities are particularly relevant. Plachouris et al. demonstrated that DL models can predict post-treatment 90Y microspheres distribution from pre-treatment 99mTc-MAA SPECT/CT. Mean absorbed dose differences of 5.42% ± 19.31% in tumors and 0.44% ± 1.64% in the liver were identified [138]. The results of this study revealed improved predictive performance when compared to conventional methods, which often fail to consider the differences in particle characteristics and therapeutic flow dynamics. In addition, dosimetry frameworks based on AI enable accelerated dose calculations at voxel-level, reducing dependencies on time-consuming MC simulations while preserving spatial accuracy. AI and DL-based auto segmentation of normal liver and liver tumors reduce inter- and intra-operator variability and increase reproducibility in absorbed dose estimations. In contrast to multi-timepoints imaging-based dosimetry, AI-based models capable of estimating activity distributions from limited imaging data, improving clinical workflow and patient comfort. Furthermore, AI can integrate imaging, clinical, and biological data to improve accuracy in dose calculation, identify toxicity risk factors, and enable adaptive treatment planning [139]. In a recent study, Woo et al. highlighted that DL approaches, including U-Net and generative adversarial networks (GANs) improve image quality, auto segmentation, and accuracy in voxel-level dose estimation while enhancing efficiency and reproducibility in dosimetry [140]. Despite this promising development, the clinical integration of AI in 90Y TARE remains at an early stage. Most of the available models are trained on limited datasets and lack generalizability across different imaging systems. Moreover, AI-based approaches typically rely on MC or voxel-based dosimetry as reference standards, indicating that further validation, standardization, and multi-center studies are required before widespread clinical adoption.
Recent advancements in medical imaging infrastructures, image registration tools and image reconstruction algorithms have emphasized a multimodal imaging approach that integrates cone-beam CT, angio-CT, and 18F-Fluoro-deoxyglucose (18F-FDG) PET to generate a comprehensive patient-specific liver map [141, 142]. These advanced imaging methods exploit the unique strengths of each modality to improve tumor visualization, vascular anatomy assessment, and dosimetry precision for optimized treatment planning. Furthermore, PET-imaging based dosimetry using 86Y is emerging in 90Y-TARE as a superior alternative to 99mTc-MAA SPECT/CT for pre-treatment planning, as it more accurately predicts the biodistribution of therapeutic microspheres and reduces discrepancies between planned and actual dose [143]. In addition, Cherenkov luminescence imaging (CLI) has been gaining importance in 90Y-TARE application. CLI is an optical imaging modality that detects visible photons emitted from 90Y, offering a label-free strategy to track 90Y-microspheres in TARE without exogenous modifications or reporters. As reviewed by Teng et al., CLI allows real-time visualization of tumor margin, with direct applicability to monitor intraprocedural 90Y microspheres distribution and post-treatment dosimetry [144]. The high energy pure β-emission of 90Y is beneficial to CLI sensitivity while eliminating γ-radiation background. This positions CLI as a promising non-invasive complement to 90Y-PET/CT in precision TARE management. Moreover, incorporating radiomics and genomic data into dosimetry models will permit more precise predictions of tumor response and toxicity, paving the way for truly personalized treatment strategies [145].
Another significant advancement in TARE is the application of computational fluid dynamics (CFD) modeling. CFD-based dosimetry software simulates the intrahepatic distribution of 90Y microspheres, enabling precise predictions of therapeutic agent dispersion within the hepatic vasculature [146, 147]. By incorporating vessel morphology/structure, arterial flow velocity profiles, and microsphere physical properties, CFD-based dosimetry frameworks may transcend the inherent limitations of population-averaged partition models and empirical BSA-based activity prescriptions, enabling truly individualized pre-treatment simulation of 90Y microsphere dispersion within the tumor-bearing hepatic vasculature. A dedicated CFD modeling study reported discrepancies of 2% to 3.5% between 90Y distributions predicted using 99mTc-MAA and actual in vivo distributions assessed via 90Y PET/CT [147]. This is underscoring the superior predictive fidelity of CFD simulation as a complementary or surrogate-independent planning tool. As clinical adoption increases and technical challenges are addressed, these advanced personalized dosimetry strategies can play a crucial role in optimizing 90Y TARE outcomes, ultimately leading to more effective and safer treatments for patients with liver cancer.
Despite their promising attributes, novel surrogate materials face substantial logistical, regulatory, and economic barriers that must be systematically addressed before widespread clinical adoption in TARE can be achieved. At the workflow level, adoption of new surrogate materials requires significant modifications of radiopharmacy procedures, imaging protocol adjustment and structured clinician training to account for surrogate-specific pharmacokinetics and biodistribution patterns. Consistency between pre-treatment simulations and actual ⁹⁰Y microsphere distributions should be thoroughly validated for each candidate surrogate, as intravascular flow dynamics and embolic properties may differ meaningfully between surrogate and therapeutic particles [114]. The regulatory pathways present an independent barrier. Clinical integration of new surrogate materials requires rigorous validation of safety and efficacy through extensive preclinical and clinical trial programs establishing equivalence or superiority over existing standards. FDA or EMA approval further mandates adherence to Good Manufacturing Practices (GMP) standard and robust quality control documentation. Infrastructure limitations compound these challenges. Broad deployment of PET- or SPECT-compatible surrogates presupposes access to appropriately equipped and optimized nuclear medicine facilities, which remain unevenly distributed across healthcare systems [148]. Economic justification, such as a cost-benefit analysis, is a further prerequisite for the clinical implementation of new surrogate materials, particularly in resource-constrained healthcare systems. While surrogate materials with superior dosimetry accuracy have the potential to reduce treatment failure rates and improve long-term patient outcomes, the upfront financial burden associated with new imaging agents, hardware upgrades, and training personnel are substantial [149]. Establishing reimbursement policies and cost-effectiveness studies will therefore be pivotal in determining the feasibility of integrating novel surrogate materials into routine clinical TARE practice.
Over the years, development of surrogate materials for pre-treatment planning of TARE has become central to bridge the gap between pre-treatment imaging and actual therapeutic radioactive microsphere deposition for enhancing therapeutic outcomes. [150]. Several emerging surrogate materials have shown meaning advances over conventional surrogates for refining pre-treatment dosimetry. PET-compatible biodegradable microspheres are suggested as next generation alternatives, offering improved dosimetry fidelity while mitigating the long-term embolic risks associated with permanent microspheres. Theranostic radionuclides labeled microspheres further integrated imaging and therapeutic into a single platform, allowing real-time dosimetry assessment and supporting personalized treatment strategies. Multimodal PET/CT/X-ray/MRI visible surrogate materials along with scout-dose strategies have demonstrated potential for improved spatial mapping of deposition and dose estimation. At the same time, MRI or CT visible nanoparticles-based systems including iron oxide and radio-opaque metal nanoparticles have been under active investigation as adjuvants for enhancing dosimetry prediction accuracy [151, 152]. In parallel, computational and AI-driven approaches are evolving in concert with these material advances. MC simulations, DL-based biodistribution prediction models, and computational fluid dynamics modeling now provide mechanistic frameworks for anticipating surrogate materials and microspheres distribution across patient specific vascular structures. AI algorithms incorporating patient-specific anatomical and physiological factors increasingly refine personalized dose planning at a level of granularity not achievable through conventional approaches [114]. In summary, these converging advances in surrogate materials, dosimetry modeling, and predictive computation approaches are anticipated to lead to improved tumor response rates, extended progression-free survival, and a reduction in complications associated with off-target radiation. Future research should prioritize optimizing and validating these technologies and focus on facilitating their integration into clinical TARE workflows to fully realize their potential in improving patient outcomes.
ADIBO-NHS: azadibenzocyclooctyne N-hydroxysuccinimide ester; AI: artificial intelligence; AVM: arteriovenous malformation; BED: biologically effective dose; CE: conformite europeenne; CT: computed tomography; DL: deep learning; DSA: digital subtraction angiography; DSM: degradable starch microsphere; DVH: dose-volume histogram; FDA: Food and Drug Administration; FTIR: Fourier transform infrared spectroscopy; GMS: gelatin microsphere; HCC: hepatocellular carcinoma; HDE: humanitarian device exemption; HSA: human serum albumin; LLS: liver-lung shunt; MAA: macroaggregated albumin; MC: Monte Carlo; microPet: micro positron emission tomography; MRI: magnetic resonance imaging; MS: microspheres; NOTA: 1,4,7-triazacyclononane-1,4,7-triacetic acid; PBS: phosphate-buffered saline; PDA: polydopamine; PET: positron emission tomography; PHBV: polyhydroxybutyrate-co-3-hydroxyvalerate; PLGA: poly(lactic-co-glycolic acid); PLLA: poly(L-lactic acid); PMMA: polymethyl methacrylate; SBMP: starch-based microspheres; SEM: scanning electron microscopy; SFM: silk fibron microspheres; SIRT: selective internal radiation therapy; SPECT: single photon emission computed tomography; TARE: trans-arterial radioembolization; VOI: volume of interest; XRD: X-ray diffraction.
This work was supported by NCI grants (No. R01CA282664, R01CA278956, and R01CA279040). Illustrations were originally created by authors through Biorender and Paint3D.
R.J.L. reports consultant roles with Boston Scientific, BD, and Varian. All other authors have declared that no competing interest exists.
1. Yang JD, Hainaut P, Gores GJ, Amadou A, Plymoth A, Roberts LR. A global view of hepatocellular carcinoma: trends, risk, prevention and management. Nat Rev Gastroenterol Hepatol. 2019;16:589
2. Reig M, Forner A, Rimola J, Ferrer-Fàbrega J, Burrel M, Garcia-Criado Á. et al. BCLC strategy for prognosis prediction and treatment recommendation: The 2022 update.J. Hepatol. 2022;76:681-93
3. Kallini JR, Gabr A, Salem R, Lewandowski RJ. Transarterial radioembolization with yttrium-90 for the treatment of hepatocellular carcinoma. Adv Ther. 2016;33:699-714
4. Spyridonidis T, Spyridonidis J, Papathanasiou N, Katsanos K. History and development of radioembolization: an old idea with modern applications. Nucl Med Commun. 2019;40:684-92
5. Muller J, Rossier P. A New Method for the Treatment of Cancer of the Lungs by Means of Artificial Radioactivity: (Zn63 and Au198): First Experimental and Clinical Studies. Acta Radiol. 1951:449-68
6. Murthy R, Nunez R, Szklaruk J, Erwin W, Madoff DC, Gupta S. et al. Yttrium-90 microsphere therapy for hepatic malignancy: devices, indications, technical considerations, and potential complications. Radiographics. 2005;25:S41-S55
7. Li R, Li D, Jia G, Li X, Sun G, Zuo C. Diagnostic performance of theranostic radionuclides used in transarterial radioembolization for liver cancer. Front Oncol. 2021;10:551622
8. Abraham RJ, Arepally A, Liu D, Lewandowski R, Kappadath SC, Verma A. et al. Imageable Radioembolization Microspheres for Treatment of Unresectable Hepatocellular Carcinoma: Interim Results from a First-in-Human Trial. J Vasc Interv Radiol. 2024;35:1464-73 e1
9. Chen K, Tong AKT, Moe FNN, Ng DCE, Lo RHG, Gogna A. et al. The impact of radiation dose and tumour burden on outcomes in hepatocellular carcinoma: 11-year experience in a 413-patient cohort treated with yttrium-90 resin microsphere radioembolisation. Liver Cancer. 2025;14:158-79
10. Zhou Y, Gao Y, Duan G, Wen L, Shan S, Wu S. et al. Radioactive Microspheres for Selective Internal Radiation Therapy of Hepatocellular Carcinoma. Adv Nanobiomed Res. 2023;3:2200166
11. Anbari Y, Veerman FE, Keane G, Braat AJ, Smits ML, Bruijnen RC. et al. Current status of yttrium-90 microspheres radioembolization in primary and metastatic liver cancer. J Interv Med. 2023;6:153-9
12. Salem R, Johnson GE, Kim E, Riaz A, Bishay V, Boucher E. et al. Yttrium-90 radioembolization for the treatment of solitary, unresectable HCC: the LEGACY study. Hepatology. 2021;74:2342-52
13. Westcott MA, Coldwell DM, Liu DM, Zikria JF. The development, commercialization, and clinical context of yttrium-90 radiolabeled resin and glass microspheres. Radiation Oncology. 2016;1:351-64
14. Reinders MT, Smits ML, van Roekel C, Braat AJ. Holmium-166 microsphere radioembolization of hepatic malignancies. Semin Nucl Med. 2019;49:237-43
15. Smits ML, Elschot M, van den Bosch MA, van de Maat GH, van het Schip AD, Zonnenberg BA. et al. In vivo dosimetry based on SPECT and MR imaging of 166Ho-microspheres for treatment of liver malignancies. J Nucl Med. 2013;54:2093-100
16. Dimopoulos PM, Sotirchos VS, Dunne-Jaffe C, Petre EN, Gonen M, Zhao K. et al. Voxel-based dosimetry predicts local tumor progression post 90Y radiation segmentectomy of colorectal liver metastases. Clin Nucl Med. 2025;50:133-42
17. Maxwell AWP, Mendoza HG, Sellitti MJ, Camacho JC, Deipolyi AR, Ziv E. et al. Optimizing 90Y Particle Density Improves Outcomes After Radioembolization: AWP Maxwell et al.: Optimizing 90Y Particle Density Improves Outcomes After Radioembolization. Cardiovasc Intervent Radiol. 2022;45:958-69
18. Wondergem M, Smits ML, Elschot M, de Jong HW, Verkooijen HM, van den Bosch MA. et al. 99mTc-macroaggregated albumin poorly predicts the intrahepatic distribution of 90Y resin microspheres in hepatic radioembolization. J Nucl Med. 2013;54:1294-301
19. Georgiou MF, Kuker RA, Studenski MT, Ahlman PP, Witte M, Portelance L. Lung shunt fraction calculation using 99mTc-MAA SPECT/CT imaging for 90Y microsphere selective internal radiation therapy of liver tumors. EJNMMI Res. 2021;11:96
20. Knešaurek K, Machac J, Muzinic M, DaCosta M, Zhang Z, Heiba S. Quantitative comparison of yttrium-90 (90 Y)-microspheres and technetium-99m (99m Tc)-macroaggregated albumin SPECT images for planning 90 Y therapy of liver cancer. Technol Cancer Res Treat. 2010;9:253-61
21. Riveira-Martin M, Akhavanallaf A, Mansouri Z, Bianchetto Wolf N, Salimi Y, Ricoeur A. et al. Predictive value of 99mTc-MAA-based dosimetry in personalized 90Y-SIRT planning for liver malignancies. EJNMMI Res. 2023;13:63
22. Alrfooh A, Patel A, Laroia S. Transarterial radioembolization agents: a review of the radionuclide agents and the carriers. Nucl Med Mol Imaging. 2021;55:162-72
23. Grosser OS, Ruf J, Kupitz D, Pethe A, Ulrich G, Genseke P. et al. Pharmacokinetics of 99mTc-MAA-and 99mTc-HSA-microspheres used in preradioembolization dosimetry: Influence on the liver-lung shunt. J Nucl Med. 2016;57:925-7
24. Wang Y-F, Chen Y-C, Li D-K, Chuang M-H. Technetium-99m-labeled autologous serum albumin: A personal-exclusive source of serum component. Biomed Res Int. 2011;2011:413802
25. Kumar A, Kulkarni S, Pandey A, Mutalik S, Subramanian S. Nano-tracers for sentinel lymph node detection: current trends in technique and application. Nanomedicine. 2024;19:59-77
26. AC07056269 A. Technetium-99m radiopharmaceuticals: manufacture of kits: Internat. Atomic Energy Agency. 2008
27. Lam MG, Goris ML, Iagaru AH, Mittra ES, Louie JD, Sze DY. Prognostic utility of 90Y radioembolization dosimetry based on fusion 99mTc-macroaggregated albumin-99mTc-sulfur colloid SPECT. J Nucl Med. 2013;54:2055-61
28. Zielhuis S, Seppenwoolde J, Bakker C, Jahnz U, Zonnenberg B, Van Het Schip A. et al. Characterization of holmium loaded alginate microspheres for multimodality imaging and therapeutic applications. J Biomed Mater Res. 2007;82:892-8
29. Seevinck PR, van de Maat GH, de Wit TC, Vente MA, Nijsen JF, Bakker CJ. Magnetic resonance imaging-based radiation-absorbed dose estimation of 166Ho microspheres in liver radioembolization. Int J Radiat Oncol Biol Phys. 2012;83:e437-e44
30. Yavari K, Yeganeh E, Abolghasemi H. Production and characterization of 166Ho polylactic acid microspheres. J Labelled Comp Radiopharm. 2016;59:24-9
31. Subramanian S, Vimalnath K, Dash A. Preparation and preliminary in vivo evaluation of 166Ho-labeled microspheres for possible use in radioembolic therapy of liver cancer. J Labelled Comp Radiopharm. 2018;61:509-14
32. Reinders MT, Braat AJ, van Erpecum KJ, de Bruijne J, Bruijnen RC, Sprengers D. et al. Holmium-166 radioembolisation dosimetry in HCC. Eur J Nucl Med Mol Imaging. 2024:1-11
33. Radosa CG, Radosa JC, Grosche-Schlee S, Zöphel K, Plodeck V, Kühn JP. et al. Holmium-166 radioembolization in hepatocellular carcinoma: feasibility and safety of a new treatment option in clinical practice. Cardiovasc Intervent Radiol. 2019;42:405-12
34. Chiesa C, Maccauro M. 166 Ho microsphere scout dose for more accurate radioembolization treatment planning. Eur J Nucl Med Mol Imaging. 2020;47:744-7
35. Bastiaannet R, van Roekel C, Smits ML, Elias SG, van Amsterdam WA, Doan D. et al. First evidence for a dose-response relationship in patients treated with 166Ho radioembolization: a prospective study. J Nucl Med. 2020;61:608-12
36. Smits ML, Dassen MG, Prince JF, Braat AJ, Beijst C, Bruijnen RC. et al. The superior predictive value of 166 Ho-scout compared with 99m Tc-macroaggregated albumin prior to 166 Ho-microspheres radioembolization in patients with liver metastases. Eur J Nucl Med Mol Imaging. 2020;47:798-806
37. Stella M, Braat AJ, Lam MG, de Jong HW, van Rooij R. Quantitative 166 Ho-microspheres SPECT derived from a dual-isotope acquisition with 99m Tc-colloid is clinically feasible. EJNMMI phys. 2020;7:1-12
38. d’Abadie P, Hesse M, Louppe A, Lhommel R, Walrand S, Jamar F. Microspheres used in liver radioembolization: from conception to clinical effects. Molecules. 2021;26:3966
39. Wunderlich G, Pinkert J, Stintz M, Kotzerke J. Labeling and biodistribution of different particle materials for radioembolization therapy with 188Re. Appl Radiat Isot. 2005;62:745-50
40. Oehme L, Kotzerke J. Radiobiological considerations for radioembolization with 188 Re-microspheres. Eur J Nucl Med Mol Imaging. 2009;36:322-5
41. Verger E, Drion P, Meffre G, Bernard C, Duwez L, Lepareur N. et al. 68Ga and 188Re starch-based microparticles as theranostic tool for the hepatocellular carcinoma: radiolabeling and preliminary in vivo rat studies. PLoS One. 2016;11:e0164626
42. Esquinas PL, Shinto A, Kamaleshwaran KK, Joseph J, Celler A. Biodistribution, pharmacokinetics, and organ-level dosimetry for 188 Re-AHDD-Lipiodol radioembolization based on quantitative post-treatment SPECT/CT scans. EJNMMI phys. 2018;5:1-22
43. Delaunay K, Edeline J, Rolland Y, Lepareur N, Laffont S, Palard X. et al. Preliminary results of the Phase 1 Lip-Re I clinical trial: biodistribution and dosimetry assessments in hepatocellular carcinoma patients treated with 188 Re-SSS lipiodol radioembolization. Eur J Nucl Med Mol Imaging. 2019;46:1506-17
44. Jamre M, Shamsaei M, Erfani M, Sadjadi S, Ghannadi Maragheh M. Preparation and evaluation of 188Re sulfide colloidal nanoparticles loaded biodegradable poly (L-lactic acid) microspheres for radioembolization therapy. J Labelled Comp Radiopharm. 2018;61:586-94
45. De La Vega JC, Esquinas PL, Rodríguez-Rodríguez C, Bokharaei M, Moskalev I, Liu D. et al. Radioembolization of hepatocellular carcinoma with built-in dosimetry: first in vivo results with uniformly-sized, biodegradable microspheres labeled with 188Re. Theranostics. 2019;9:868
46. Hashikin NAA, Yeong C-H, Abdullah BJJ, Ng K-H, Chung L-Y, Dahalan R. et al. Neutron activated samarium-153 microparticles for transarterial radioembolization of liver tumour with post-procedure imaging capabilities. PLoS One. 2015;10:e0138106
47. Wong YH, Tan HY, Kasbollah A, Abdullah BJJ, Yeong CH. Preparation and in vitro evaluation of neutron-activated, theranostic samarium-153-labeled microspheres for transarterial radioembolization of hepatocellular carcinoma and liver metastasis. Pharmaceutics. 2019;11:596
48. Wong Y-H, Tan H-Y, Kasbollah A, Abdullah BJJ, Acharya RU, Yeong C-H. Neutron-activated biodegradable samarium-153 acetylacetonate-poly-L-lactic acid microspheres for intraarterial radioembolization of hepatic tumors. World J Exp Med. 2020;10:10
49. Tan HY, Wong YH, Kasbollah A, Shah MNM, Abdullah BJJ, Perkins AC. et al. Development of neutron-activated samarium-153-loaded polystyrene microspheres as a potential theranostic agent for hepatic radioembolization. Nucl Med Commun. 2022;43:410-22
50. Alregib AH, Tan HY, Wong YH, Kasbollah A, Wong EH, Abdullah BJJ. et al. Development and physicochemical characterization of a biodegradable microspheres formulation loaded with samarium-153 and doxorubicin for chemo-radioembolization of liver tumours. J Labelled Comp Radiopharm. 2023;66:308-20
51. Wong YH, Kasbollah A, Abdullah BJJ, Yeong CH. Facile Preparation of Samarium Carbonate-Polymethacrylate Microspheres as a Neutron-Activatable Radioembolic Agent for Hepatic Radioembolization. Pharmaceutics. 2023;15:877
52. Ma Y, Wan Y, Luo D-H, Duan L-G, Li L, Xia C-Q. et al. Direct in vivo injection of 131I-GMS and its distribution and excretion in rabbit. World J Gastroenterol. 2010;16:2120
53. Chi J-L, Li C-C, Xia C-Q, Li L, Ma Y, Li J-H. et al. Effect of 131I gelatin microspheres on hepatocellular carcinoma in nude mice and its distribution after intratumoral injection. Radiat Res. 2014;181:416-24
54. Lintia-Gaultier A, Perret C, Ansquer C, Eugene T, Kraeber-Bodere F, Frampas E. Intra-arterial injection of 131I-labeled Lipiodol for advanced hepatocellular carcinoma: a 7 years’ experience. Nucl Med Commun. 2013;34:674-81
55. Hwang H, Kim KI, Kwon J, Kim BS, Jeong H-S, Jang SJ. et al. 131I-labeled chitosan hydrogels for radioembolization: A preclinical study in small animals. Nucl Med Biol. 2017;52:16-23
56. Pang F, Li Y, Zhang W, Xia C, He Q, Li Z. et al. Biodegradable 131Iodine-Labeled Microspheres: Potential Transarterial Radioembolization Biomaterial for Primary Hepatocellular Carcinoma Treatment. Adv Healthc Mater. 2020;9:2000028
57. Wu X, Ge L, Shen G, He Y, Xu Z, Li D. et al. 131I-labeled silk fibroin microspheres for radioembolic therapy of rat hepatocellular carcinoma. ACS Appl Mater Interfaces. 2022;14:21848-59
58. Chan H-W, Lo Y-H, Chang D-Y, Li J-J, Chang W-Y, Chen C-H. et al. Radiometal-labeled chitosan microspheres as transarterial radioembolization agents against hepatocellular carcinoma. Gels. 2022;8:180
59. Wu M, Zhang L, Shi K, Zhao D, Yong W, Yin L. et al. Polydopamine-coated radiolabeled microspheres for combinatorial radioembolization and photothermal cancer therapy. ACS Appl Mater Interfaces. 2023;15:12669-77
60. Yang S, Mu C, Liu T, Pei P, Shen W, Zhang Y. et al. Radionuclide-Labeled Microspheres for Radio-Immunotherapy of Hepatocellular Carcinoma. Adv Healthc Mater. 2023;12:2300944
61. Jin S, Huang J, Dong Y, Hu D, Sun J, Li Z. et al. Ultrastable PLGA-Coated 177Lu-Microspheres for Radioembolization Therapy of Hepatocellular Carcinoma. Mol Pharm. 2024
62. Xiao L, Li Y, Geng R, Chen L, Yang P, Li M. et al. Polymer composite microspheres loading 177Lu radionuclide for interventional radioembolization therapy and real-time SPECT imaging of hepatic cancer. Biomater Res. 2023;27:110
63. Jamre M, Shamsaei M, Maragheh MG, Sadjadi S. Novel 175Yb-poly (L-Lactic acid) microspheres for transarterial radioembolization of unrespectable hepatocellular carcinoma. Iran J Pharm Res. 2019;18:569
64. Ferreira MCM, Podder TK, Rasmussen KH, Jung JW. Praseodymium-142 microspheres for brachytherapy of nonresectable hepatic tumors. Brachytherapy. 2013;12:654-64
65. Nijsen J, Zonnenberg B, Woittiez J, Rook D, Swildens-van Woudenberg I, Van Rijk P. et al. Holmium-166 poly lactic acid microspheres applicable for intra-arterial radionuclide therapy of hepatic malignancies: effects of preparation and neutron activation techniques. Eur J Nucl Med. 1999;26:699-704
66. Welling MM, Duszenko N, van Meerbeek MP, Molenaar TJ, Buckle T, van Leeuwen FW. et al. Microspheres as a carrier system for therapeutic embolization procedures: Achievements and advances. J Clin Med. 2023;12:918
67. Partensky C, Sassolas G, Henry L, Paliard P, Maddern GJ. Intra-arterial iodine 131-labeled lipiodol as adjuvant therapy after curative liver resection for hepatocellular carcinoma: a phase 2 clinical study. Arch Surg. 2000;135:1298-300
68. Ahmadzadehfar H, Sabet A, Wilhelm K, Biersack HJ, Risse J. Iodine-131-lipiodol therapy in hepatic tumours. Methods. 2011;55:246-52
69. Kim K, Kim S-J. Lu-177-based peptide receptor radionuclide therapy for advanced neuroendocrine tumors. Nucl Med Mol Imaging. 2018;52:208-15
70. Li J, Zhang L, Li W, Lei C, Cao Y, Wang Y. et al. Preparation and SPECT/CT Imaging of 177Lu-Labeled Peptide Nucleic Acid (PNA) Targeting CITED1: Therapeutic Evaluation in Tumor-Bearing Nude Mice. Onco Targets Ther. 2020:487-96
71. Lee S-W, Reece WD. Dose calculation of 142Pr microspheres as a potential treatment for arteriovenous malformations. Phys Med Biol. 2004;50:151
72. Chakraborty S, Unni P, Venkatesh M, Pillai M. Feasibility study for production of 175Yb: a promising therapeutic radionuclide. Appl Radiat Isot. 2002;57:295-301
73. Mathew B, Chakraborty S, Das T, Sarma H, Banerjee S, Samuel G. et al. 175Yb labeled polyaminophosphonates as potential agents for bone pain palliation. Appl Radiat Isot. 2004;60:635-42
74. Chakraborty S, Vimalnath K, Rajeswari A, Sarma H, Shinto A, Radhakrishnan E. et al. Radiolanthanide-labeled HA particles in the treatment of rheumatoid arthritis: ready-to-use cold kits for rapid formulation in hospital radiopharmacy. J Radioanal Nucl Chem. 2014;302:875-81
75. Kokabi N, Webster LA, Elsayed M, Switchenko JM, Chen B, Brandon D. et al. Accuracy and safety of scout dose resin yttrium-90 microspheres for radioembolization therapy treatment planning: a prospective single-arm clinical trial. J Vasc Interv Radiol. 2022;33:1578-87 e5
76. Mumper RJ, Jay M. Biodegradable radiotherapeutic polyester microspheres: optimization and in-vitro/in-vivo evaluation. J Control Release. 1992;18:193-203
77. Nijsen J, Schip Avh, Hennink W, Rook D, Van Rijk P, Klerk J. Advances in nuclear oncology: microspheres for internal radionuclide therapy of liver tumours. Curr Med Chem. 2002;9:73-82
78. Cai H, Li A, Qi F, Liu R, Tang X, Li D. et al. Application of biodegradable microsphere injections: an anticancer perspective. Mater Adv. 2024;5:3094-112
79. Moschovaki-Zeiger O, Arkoudis N-A, Giannakis A, Grigoriadis S, Anagnostopoulos F, Spiliopoulos S. Biodegradable Microspheres for Transarterial Chemoembolization in Malignant Liver Disease. Medicina. 2024;60:678
80. Doucet J, Kiri L, O’Connell K, Kehoe S, Lewandowski RJ, Liu DM. et al. Advances in degradable embolic microspheres: a state of the art review. J Funct Biomater. 2018;9:14
81. Holmium-166 Retrospective Collection of Real-World Data. 2021
82. Individualized Dosimetry for Holmium-166 Radioembolization in Patients With Unresectable Hepatocellular Carcinoma; a Multi-centre, Interventional, Non-randomized, Non-comparative, Open Label, Early Phase II Study. In: Terumo Europe NV, editor.; 2024
83. Park W, Chen J, Cho S, Park S-j, Larson AC, Na K. et al. Acidic pH-triggered drug-eluting nanocomposites for magnetic resonance imaging-monitored intra-arterial drug delivery to hepatocellular carcinoma. ACS Appl Mater Interfaces. 2016;8:12711-9
84. Park W, Cho S, Ji J, Lewandowski RJ, Larson AC, Kim D-H. Development and validation of sorafenib-eluting microspheres to enhance therapeutic efficacy of transcatheter arterial chemoembolization in a rat model of hepatocellular carcinoma. Radiol Imaging Cancer. 2021;3:e200006
85. Shukla J, Bandopadhyaya G, Varma I. 188Rhenium (V)-dimercaptosuccinic acid loaded poly (lactic-co-glycolic) acid microspheres for targeted radiotherapy: production and effectivity. Die Pharmazie-An International J Pharm Sci. 2005;60:583-7
86. Liu D, Nikoo M, Boran G, Zhou P, Regenstein JM. Collagen and gelatin. Annu Rev Food Sci Technol. 2015;6:527-57
87. Gao F, Rafiq M, Cong H, Yu B, Shen Y. Current research status and development prospects of embolic microspheres containing biological macromolecules and others. Int J Biol Macromol. 2024: 131494.
88. He S, Wang J, Li Z, Cao Y, Ning X, Sun J. et al. Reversible cross-linking of gelatin by a disulphide-containing bis-succinimide for tunable degradation and release. Food Chem X. 2023;18:100699
89. Gupta A, Park JY, Choi H, Choi TH, Chung Y, Kim D-H. et al. Development of Alginate-Based Biodegradable Radioactive Microspheres Labeled with Positron Emitter through Click Chemistry Reaction: Stability and PET Imaging Study. Mol Pharm. 2024;21:5005-14
90. Orlacchio A, Chegai F, Merolla S, Francioso S, Del Giudice C, Angelico M. et al. Downstaging disease in patients with hepatocellular carcinoma outside up-to-seven criteria: Strategies using degradable starch microspheres transcatheter arterial chemo-embolization. World J Hepatol. 2015;7:1694
91. Avila-Rodriguez MA, Selwyn RG, Hampel JA, Thomadsen BR, DeJesus OT, Converse AK. et al. Positron-emitting resin microspheres as surrogates of 90Y SIR-Spheres: a radiolabeling and stability study. Nucl Med Biol. 2007;34:585-90
92. Selwyn R, Avila-Rodriguez M, Converse A, Hampel J, Jaskowiak C, McDermott J. et al. 18F-labeled resin microspheres as surrogates for 90Y resin microspheres used in the treatment of hepatic tumors: a radiolabeling and PET validation study. Phys Med Biol. 2007;52:7397
93. Chambers GD. Development of a Positron-Emitting Surrogate Microsphere for Image-Based Dosimetry in Yttrium-90 Radioembolization Therapy: The University of New Mexico; 2018
94. Larsen LI, López GP, Selwyn R, Carroll NJ. Microfluidic fabrication of silica microspheres infused with positron emission tomography imaging agents. ACS Applied Bio Materials. 2023;6:712-21
95. Choi H, Choi B, Yu B, Li W, Matsumoto MM, Harris KR. et al. On-demand degradable embolic microspheres for immediate restoration of blood flow during image-guided embolization procedures. Biomaterials. 2021;265:120408
96. Shi H, Niu M, Tan L, Liu T, Shao H, Fu C. et al. A smart all-in-one theranostic platform for CT imaging guided tumor microwave thermotherapy based on IL@ ZrO 2 nanoparticles. Chem Sci. 2015;6:5016-26
97. Wang D, Rao W. Bench-to-bedside development of multifunctional flexible embolic agents. Theranostics. 2023;13:2114
98. Kim D-H, Li W, Chen J, Zhang Z, Green RM, Huang S. et al. Multimodal imaging of nanocomposite microspheres for transcatheter intra-arterial drug delivery to liver tumors. Sci Rep. 2016;6:29653
99. Lewis AL, Willis SL, Dreher MR, Tang Y, Ashrafi K, Wood BJ. et al. Bench-to-clinic development of imageable drug-eluting embolization beads: finding the balance. Future Oncol. 2018;14:2741-60
100. Caine M, Carugo D, Zhang X, Hill M, Dreher MR, Lewis AL. Review of the development of methods for characterization of microspheres for use in embolotherapy: translating bench to cathlab. Adv Healthc Mater. 2017;6:1601291
101. Zeng J, Li L, Zhang H, Li J, Liu L, Zhou G. et al. Radiopaque and uniform alginate microspheres loaded with tantalum nanoparticles for real-time imaging during transcatheter arterial embolization. Theranostics. 2018;8:4591
102. Henry EC, Strugari M, Mawko G, Brewer KD, Abraham R, Kappadath SC. et al. Post-administration dosimetry in yttrium-90 radioembolization through micro-CT imaging of radiopaque microspheres in a porcine renal model. Phys Med Biol. 2021;66:095011
103. Henry EC, Strugari M, Mawko G, Brewer K, Liu D, Gordon AC. et al. Precision dosimetry in yttrium-90 radioembolization through CT imaging of radiopaque microspheres in a rabbit liver model. EJNMMI phys. 2022;9:21
104. Henry EC, Strugari M, Mawko G, Brewer K, Liu D, Gordon AC. et al. Correction: Precision dosimetry in yttrium-90 radioembolization through CT imaging of radiopaque microspheres in a rabbit liver model. EJNMMI phys. 2023;10:74
105. Chen J, Sheu AY, Li W, Zhang Z, Kim D-H, Lewandowski RJ. et al. Poly (lactide-co-glycolide) microspheres for MRI-monitored transcatheter delivery of sorafenib to liver tumors. J of control release. 2014;184:10-7
106. Chen J, White SB, Harris KR, Li W, Yap JWT, Kim D-H. et al. Poly (lactide-co-glycolide) microspheres for MRI-monitored delivery of sorafenib in a rabbit VX2 model. Biomaterials. 2015;61:299-306
107. Kim D-H, Chen J, Omary RA, Larson AC. MRI visible drug eluting magnetic microspheres for transcatheter intra-arterial delivery to liver tumors. Theranostics. 2015;5:477
108. Li W, Zhang Z, Gordon AC, Chen J, Nicolai J, Lewandowski RJ. et al. SPIO-labeled yttrium microspheres for MR imaging quantification of transcatheter intrahepatic delivery in a rodent model. Radiology. 2016;278:405-12
109. Qin X-Y, Liu X-X, Li Z-Y, Guo L-Y, Zheng Z-Z, Guan H-T. et al. MRI Detectable polymer microspheres embedded with magnetic ferrite nanoclusters for embolization: In vitro and in vivo evaluation. Int J Nanomedicine. 2019:8989-9006
110. Wang Q, Xiao A, Liu Y, Zou Q, Zhou Q, Wang H. et al. One-step preparation of nano-in-micro poly (vinyl alcohol) embolic microspheres and used for dual-modal T1/T2-weighted magnetic resonance imaging. Nanomedicine. 2018;14:2551-61
111. Tacher V, Duran R, Lin M, Sohn JH, Sharma KV, Wang Z. et al. Multimodality imaging of ethiodized oil-loaded radiopaque microspheres during transarterial embolization of rabbits with VX2 liver tumors. Radiology. 2016;279:741-53
112. Wang Q, Liu S, Yang F, Gan L, Yang X, Yang Y. Magnetic alginate microspheres detected by MRI fabricated using microfluidic technique and release behavior of encapsulated dual drugs. Int J Nanomedicine. 2017:4335-47
113. Stephens RW, Tredwell GD, Knox KJ, Philip LA, King DW, Debono KM. et al. 99mTc-radiolabeled composites enabling in vivo imaging of arterial dispersal and retention of microspheres in the vascular network of rabbit lungs, liver, and liver tumors. Int J Nanomedicine. 2019:889-900
114. Knight GM, Gordon AC, Gates V, Talwar A, Riaz A, Salem R. et al. Evolution of personalized dosimetry for radioembolization of hepatocellular carcinoma. J Vasc Interv Radiol. 2023;34:1214-25
115. Bozkurt MF, Salanci BV, Uğur Ö. Intra-arterial radionuclide therapies for liver tumors. Semin Nucl Med. 2016;46:324-39
116. Goin JE, Salem R, Carr BI, Dancey JE, Soulen MC, Geschwind J-FH. et al. Treatment of unresectable hepatocellular carcinoma with intrahepatic yttrium 90 microspheres: a risk-stratification analysis. J Vasc Interv Radiol. 2005;16:195-203
117. Salem R, Padia SA, Lam M, Chiesa C, Haste P, Sangro B. et al. Clinical, dosimetric, and reporting considerations for Y-90 glass microspheres in hepatocellular carcinoma: updated 2022 recommendations from an international multidisciplinary working group. Eur J Nucl Med Mol Imaging. 2023;50:328-43
118. Garin E, Tselikas L, Guiu B, Chalaye J, Edeline J, de Baere T. et al. Personalised versus standard dosimetry approach of selective internal radiation therapy in patients with locally advanced hepatocellular carcinoma (DOSISPHERE-01): a randomised, multicentre, open-label phase 2 trial. Lancet Gastroenterol Hepatol. 2021;6:17-29
119. Kim SP, Cohalan C, Kopek N, Enger SA. A guide to 90Y radioembolization and its dosimetry. Physica Medica. 2019;68:132-45
120. Garin E, Guiu B, Edeline J, Rolland Y, Palard X. Trans-arterial radioembolization dosimetry in 2022. Cardiovasc Intervent Radiol. 2022;45:1608-21
121. Mosconi C, Cappelli A, Pettinato C, Golfieri R. Radioembolization with Yttrium-90 microspheres in hepatocellular carcinoma: Role and perspectives. World J of Hepatol. 2015;7:738-752
122. Kao YH, Tan EH, Ng CE, Goh SW. Clinical implications of the body surface area method versus partition model dosimetry for yttrium-90 radioembolization using resin microspheres: a technical review. Ann Nucl Med. 2011;25:455-61
123. Mikell JK, Dewaraja YK, Owen D. Transarterial radioembolization for hepatocellular carcinoma and hepatic metastases: Clinical aspects and dosimetry models. Semin Nucl Med. 2020;30:68-76
124. Dewaraja YK, Devasia T, Kaza RK, Mikell JK, Owen D, Roberson PL. et al. Prediction of tumor control in 90Y radioembolization by logit models with PET/CT-based dose metrics. J NuclMed. 2020;61:104-11
125. Morán V, Prieto E, Sancho L, Rodríguez-Fraile M, Soria L, Zubiria A. et al. Impact of the dosimetry approach on the resulting 90 Y radioembolization planned absorbed doses based on 99m Tc-MAA SPECT-CT: is there agreement between dosimetry methods? EJNMMI phys. 2020;7:1-22
126. O’Doherty J. A review of 3D image-based dosimetry, technical considerations and emerging perspectives in 90Y microsphere therapy. J Diagn Imaging Ther. 2015;2:1
127. Roosen J, Westlund Gotby LE, Arntz MJ, Fütterer JJ, Janssen MJ, Konijnenberg MW. et al. Intraprocedural MRI-based dosimetry during transarterial radioembolization of liver tumours with holmium-166 microspheres (EMERITUS-1): a phase I trial towards adaptive, image-controlled treatment delivery. Eur J Nucl Med Mol Imaging. 2022;49:4705-15
128. Gupta A, Lee MS, Kim JH, Lee DS, Lee JS. Preclinical voxel-based dosimetry in theranostics: a review. Nucl Med Mol Imaging. 2020;54:86-97
129. Lee MS, Kim JH, Paeng JC, Kang KW, Jeong JM, Lee DS. et al. Whole-body voxel-based personalized dosimetry: the multiple voxel S-value approach for heterogeneous media with nonuniform activity distributions. J Nucl Med. 2018;59:1133-9
130. Gupta A, Shin JH, Lee MS, Park JY, Kim K, Kim JH. et al. Voxel-based dosimetry of iron oxide nanoparticle-conjugated 177Lu-labeled folic acid using SPECT/CT imaging of mice. Mol Pharm. 2019;16:1498-1506
131. d’Andrea E, Lanconelli N, Cremonesi M, Patera V, Pacilio M. The Essential Role of Monte Carlo Simulations for Lung Dosimetry in Liver Radioembolization with 90Y Microspheres. Appl Sci. 2024;14:7684
132. Lee MS, Hwang D, Kim JH, Lee JS. Deep-dose: a voxel dose estimation method using deep convolutional neural network for personalized internal dosimetry. Sci Rep. 2019;9:10308
133. Kawamura M, Kamomae T, Yanagawa M, Kamagata K, Fujita S, Ueda D. et al. Revolutionizing radiation therapy: the role of AI in clinical practice. J Radiat Res. 2024;65:1-9
134. Jiang C, Ji T, Qiao Q. Application and progress of artificial intelligence in radiation therapy dose prediction. Clin Transl Radiat Oncol. 2024: 100792.
135. Kim KM, Lee MS, Suh MS, Cheon GJ, Lee JS. Voxel-Based Internal Dosimetry for 177Lu-Labeled Radiopharmaceutical Therapy Using Deep Residual Learning. Nucl Med Mol Imaging. 2023;57:94-102
136. Ha S, Kang H, Kang D-s, Jang J, Oh JS, Sung W. A deep learning-based framework for patient-specific radiation dose prediction in beta-emitting radionuclide therapies. Phys Med Biol. 2026;71:085006
137. Ahn SH, Kim E, Kim C, Cheon W, Kim M, Lee SB. et al. Deep learning method for prediction of patient-specific dose distribution in breast cancer. Radiat Oncol. 2021;16:154
138. Plachouris D, Tzolas I, Gatos I, Papadimitroulas P, Spyridonidis T, Apostolopoulos D. et al. A deep-learning-based prediction model for the biodistribution of 90Y microspheres in liver radioembolization. Med phys. 2021;48:7427-38
139. Moraitis A, Küper A, Tran-Gia J, Eberlein U, Chen Y, Seifert R. et al. Future perspectives of artificial intelligence in bone marrow dosimetry and individualized radioligand therapy. Semin Nucl Med. 2024;54:460-9
140. Woo S-K. The role of artificial intelligence in advancing theranostics dosimetry for cancer therapy: A review. Nucl Med Mol Imaging. 2025;59:329-41
141. Jafargholi Rangraz E, Coudyzer W, Maleux G, Baete K, Deroose CM, Nuyts J. Multi-modal image analysis for semi-automatic segmentation of the total liver and liver arterial perfusion territories for radioembolization. EJNMMI res. 2019;9:1-21
142. Jafargholi Rangraz E, Tang X, Van Laeken C, Maleux G, Dekervel J, Van Cutsem E. et al. Quantitative comparison of pre-treatment predictive and post-treatment measured dosimetry for selective internal radiation therapy using cone-beam CT for tumor and liver perfusion territory definition. EJNMMI res. 2020;10:1-20
143. Le Fur M, Caravan P. 86Y PET imaging. Methods Enzymol. 2021;651:313-42
144. Teng M, Liang X, Liu H, Li Z, Gao X, Zhang C. et al. Cerenkov radiation shining a light for cancer theranostics. Nano Today. 2024;55:102174
145. Wei L, Cui C, Xu J, Kaza R, El Naqa I, Dewaraja YK. Tumor response prediction in 90 Y radioembolization with PET-based radiomics features and absorbed dose metrics. EJNMMI phys. 2020;7:1-19
146. Kretz D, Hesser J, Glatting G, Diehl S, Wenz F, He W. et al. Modeling sphere dynamics in blood vessels for SIRT pre-planning-To fathom the potential and limitations. Z Med Phys. 2019;29:5-15.147
147. Antón R, Antoñana J, Aramburu J, Ezponda A, Prieto E, Andonegui A. et al. A proof-of-concept study of the in-vivo validation of a computational fluid dynamics model of personalized radioembolization. Sci Rep. 2021;11:3895
148. Young S, Goldberg D, Hannallah J, Struycken L, Woodhead G. Advancing Radioembolization Through Personalized Dosimetry. Adv Clin Radiol. 2024;6:55-64
149. Mansur A, Habibollahi P, Fang A, Mahvash A, Etezadi V, Liddell RP. et al. New frontiers in radioembolization. Ther Adv Med Oncol. 2024;16:17588359241280692
150. Serhal M, Gordon AC, Brown DB, Toskich BB, Lewandowski RJ. Transarterial Radioembolization: Overview of Radioembolic Devices. Semin Intervent Radiol. 2023;40:461-6
151. Talebi AS, Rajabi H, Watabe H. Role of nanoparticles in transarterial radioembolization with glass microspheres. Ann Nucl Med. 2022;36:479-87
152. Talebi AS, Mehnati P, Rajabi H, Rezaei H, Geramifar P. Precision individual dosimetry in Yttrium-90 Transarterial Radioembolization in the presence of Au nanoparticles. Radiat Phys Chem. 2024: 111888.
Corresponding author: Prof. Dong-Hyun Kim, Ph.D. (Email: dhkimedu).